]> git.uio.no Git - u/mrichter/AliRoot.git/blob - MUON/READMEmchda.txt
Added some more scripts
[u/mrichter/AliRoot.git] / MUON / READMEmchda.txt
1 // $Id$
2
3 /*! 
4
5 \page README_mchda Tracking DA
6  
7 The detector algorithms are implemented for the Muon Tracking in the AliRoot framework.
8 We currently have 3 DAs for MCH :
9
10 - MUONTRKPEDda.cxx for PEDESTAL runs, running at the end of data taking on each LDC.
11 - MUONTRKGAINda.cxx for CALIBRATION runs, running at the end of data taking on each LDC.
12 - MUONTRKOCCda.cxx for PHYSICS runs, running during data taking on each LDC.
13
14 \section da_s1 The Muon Tracking Calibration
15
16 The Muon tracking chambers needs three types of calibration in order to work properly 
17 (to be more precise pedestals are required, gains are needed to get the best charge measurement possible, and the occupancy
18  is needed in order not to spend all the reconstruction time in hot-spots). 
19
20 \subsection da_ss1 Pedestals
21
22 The front-end electronics performs an online zero suppression using a threshold level.
23 Those threshold levels for all channels (~ 1 million) have to be computed in a dedicated
24 PEDESTALS runs. During this runs the zero suppression is OFF and the pedestal level and the noise is obtained for each channel. The threshold for the FEE is obtained adding the pedestal level to 3 sigmas of the noise. 
25
26 The typical ECS sequence for pedestals is :
27
28 - Switch ON the electronics LV
29 - Boot the CROCUS 
30 - Configuration 
31 - Saving Configuration in an ascii file then transferring in the File eXchange Server (FXS)
32 - Zero suppression OFF
33 - Data taking (typically 400 events)
34 - The DA computes the mean and sigma (it runs in each LDC)
35 - The DA writes one ASCII file per LDC with the results in the File Exchange Server
36
37 Then the SHUTTLE process the ASCII files and store the result on the OCDB (Keyword=PEDESTALS)
38 Only configuration files corresponding to a change of the Muon Tracker configuration are written in the FXS (Keyword=CONFIG).
39
40
41 \subsection da_ss2 Electronics gain
42
43 In order to perform the required spatial resolution or the tracking chambers (~ 100 microns),
44 we need to calibrate the gain of each channel. The gain is computed using dedicated runs where
45 a signal (DAC) is send to the chambers FEE. 
46
47 The typical ECS sequence for calibration is :
48
49 - Switch ON the electronics LV
50 - Boot the CROCUS 
51 - Configuration 
52 - Zero suppression OFF
53 - Loop of 11 data taking (typically 400 events) each with a different signal (DAC=0-200- 400-800-1200-1600-2000-2500-3000-3500-4000)
54 - The DA computes the mean and sigma (it runs in each LDC) for each run
55 - At the end of the last run, the DA computes, by using a fitting procedure, linear and parabolic gain parameters, and writes results in one ASCII file per LDC. Every ascii files are transferred in the FXS.
56
57 Then the SHUTTLE process the ASCII files and store the result on the OCDB (KEYWORD=GAINS)
58
59 \subsection da_ss3 Occupancy
60
61 For PHYSICS (or STANDALONE) runs, the MUONTRKOCCda, which is a monitoring DA, keep track of how many times
62  each channel has been hit during the run. The output is an ASCII file containing the needed information to 
63  compute the occupancy values. This file is written to the DAQ FXS so the SHUTTLE can transfer it to the OCDB.
64
65 \section da_s2 Using the DA Online
66
67 \subsection da_ss1 Pedestals
68
69 The syntax is: MUONTRKPEDda.exe "raw data file"
70
71 Two input files located in the DAQ Detector database (DetDB) are needed:
72
73 - muontrkpedvalues is built in flight in CONFIGURATION_PED.sh (ECS script) and contains one parameter "config" : 
74   config = 1 if configuration file has to be used (OnLine case)
75   config = 0 if not (OffLine case for the time being)
76   
77 - config_ldc-MTRK-S3-0 : configuration file name corresponding to MuonTracker Station 3 if (for example) DA is running on ldc-MTRK-S3-0
78
79 - DA validation: see Header of MUONTRKPEDda.cxx for reference run, and corresponding input mutrkpedvalues and configuration files are located in path=/afs/cern.ch/user/j/jcharvet/public/DA_validation
80
81 \subsection da_ss2 Electonics gain
82
83 The syntax is: MUONTRKGAINda.exe "raw data file"
84
85 Two input files located in the DAQ Detector database (DetDB) are needed:
86
87 - muontrkcalibvalues: which attributes to each run index (1->11) its corrresponding DAC value. The other parameters are used to tune the fit procedure (for expert). The last parameter indicates the number of events to be read: if "0" all events in the run are read, if not the parameter indicates the maximum number of events to be read. 
88 Default values are listed below
89
90 \verbatim
91 1 0                     
92 2 200
93 3 400
94 4 800
95 5 1200
96 6 1600
97 7 2000
98 8 2500
99 9 3000
100 10 3500
101 11 4000
102 1                                               
103 6
104 0
105 1
106 1
107 0
108 \endverbatim
109
110  - config_ldc-MTRK-S3-0 : configuration file name corresponding to MuonTracker station 3 if (for example) DA is running on ldc-MTRK-S3-0 
111
112 - DA validation: Header of MUONTRKGAINda.cxx shows the list of the 11 reference runs, and corresponding input mutrkcalibvalues and configuration files are located in path=/afs/cern.ch/user/j/jcharvet/public/DA_validation
113
114 \section da_s3 Using the DA Offline
115  
116 The DAs normally runs with a RAW data DATE format as input
117 The development of an Offline version is under way.
118
119 Nevertheless, Pedestal runs can be analysed locally, but without detector configuration file.  If you get a file in root format (e.g. from alien), you can de-rootify it using the
120   "deroot" program which is part of aliroot. 
121 Note that PED and GAIN DAs work with ROOT input files as well.
122
123 You have a line command help. To have it just type :
124
125 \verbatim
126 > MUONTRKPEDda.exe -h
127
128 ******************* ./MUONTRKPEDda.exe usage **********************
129 Online (called from ECS) : ./MUONTRKPEDda.exe <raw data file> (no inline options)
130
131 ./MUONTRKPEDda.exe can be used locally only with options (without DiMuon configuration file)
132 ./MUONTRKPEDda.exe -options, the available options are :
133 -h help                    (this screen)
134
135  Input
136 -f <raw data file>         (default = )
137
138  Output
139 -a <Flat ASCII file>       (default = MUONTRKPEDda.ped)
140
141  Options
142 -m <max date events>       (default = 1000000)
143 -s <skip events>           (default = 0)
144 -n <max events>            (default = 1000000)
145
146 \endverbatim
147
148   
149 \section da_s4 In case of trouble
150
151 Please contact :
152
153 Jean-Luc Charvet : jean-luc.charvet@cern.ch 
154 or
155 Alberto Baldisseri : a.baldisseri@cea.fr
156 or
157 Laurent Aphecetche : laurent.aphecetche@subatech.in2p3.fr (for OCC DA)
158