]>
Commit | Line | Data |
---|---|---|
c98e3298 | 1 | 3.6.4 2011-01-04 |
2 | ------------------ | |
3 | ||
4 | * Added more robustness wrt. values from OMSA obtained via SNMP, to | |
5 | avoid internal errors where non-important values are missing. | |
6 | ||
c9ffa70e | 7 | 3.6.3 2010-12-13 |
8 | ------------------ | |
9 | ||
10 | * A few compatibility fixes for OMSA 6.4.0 were added. | |
11 | ||
12 | 3.6.2 2010-11-25 | |
d57c3cb0 | 13 | ------------------ |
14 | ||
15 | * Added support for IPv6 when checking via SNMP. IPv6 can be turned on | |
16 | with the option '-6' or '--ipv6'. The default is IPv4 if the option | |
17 | is not present. | |
18 | * Added support for TCP when checking vis SNMP. The option '--tcp' can | |
19 | be used to turn on TCP. The default transport protocol is UDP if the | |
20 | option is not present. | |
df17fc3c | 21 | * The mode of operation (local or SNMP) is shown in the debug |
22 | output. If SNMP is used, the debug output will also show the SNMP | |
23 | protocol version, IP version and transport protocol (UDP or TCP). | |
c9ffa70e | 24 | * Amperage probe status via SNMP is of type "probe status", not |
25 | regular status. This has been fixed. | |
26 | * Massive overall robustness improvements to handle OMSA bugs where | |
27 | some information from OMSA is missing. | |
28 | * Memory module enumeration via SNMP changed somewhat to reflect | |
29 | enumeration provided by omreport. This ensures that the plugin's | |
30 | output is identical in SNMP or local mode wrt. dimms IDs. | |
31 | * Fan enumeration via SNMP changed somewhat to reflect enumeration | |
32 | provided by omreport. This ensures that the plugin's output is | |
33 | identical in SNMP or local mode wrt. fan IDs. | |
d57c3cb0 | 34 | |
b49f8fda | 35 | 3.6.1 2010-11-02 |
2254d3c5 | 36 | ------------------ |
37 | ||
38 | * Included new check for SD cards. Newer servers such as the R710 can | |
39 | have SD cards installed, these should be monitored. The SD card | |
40 | check is on by default. A new blacklisting keyword 'sd' has been | |
41 | added. The SD card check can be turned off with '--check sdcard=0'. | |
42 | * Handle special cases where power monitoring capability is disabled | |
43 | due to non-redundant and/or non-instrumented power supplies. | |
44 | * For physical disks probed via SNMP, check that values for vendor, | |
45 | product ID and capacity is available before attempting to display | |
46 | those values. | |
47 | * If a physical disk is in sufficiently bad condition, the vendor | |
48 | field reported by OMSA may be empty. The plugin now handles this | |
49 | situation without throwing an internal error. | |
50 | ||
51 | ||
84079ac7 | 52 | 3.6.0 2010-08-30 |
53 | ------------------ | |
54 | ||
55 | * Storage is no longer allowed to be absent. If the plugin doesn't | |
56 | find a storage controller, it will give an alert. For diskless | |
57 | systems or servers without a Dell controller that OMSA recognizes | |
58 | you will now have to specify '--no-storage' or '--check storage=0' | |
59 | to work around this. | |
60 | * Report the system revision (if applicable) wherever the model name | |
61 | is printed. E.g. "PowerEdge 2950 III" instead of "PowerEdge 2950". | |
62 | * Small change in search path for omreport: The new location for OMSA | |
63 | 6.2.0 and later on Linux will be attempted first. | |
64 | * Small bugfix for the '--check' parameter, if the argument is a | |
65 | filename. The file could not contain a linebreak, this has been | |
66 | fixed. | |
67 | * Added an option '--no-storage', which is equivalent to the general | |
68 | option '--check storage=0'. | |
69 | ||
70 | ||
5ee885c1 | 71 | 3.5.10 2010-07-14 |
72 | ------------------ | |
73 | ||
74 | * If a physical disk is a hot spare, display this information in | |
75 | the debug output | |
76 | * Report the bus protocol (e.g. SAS, SATA) and media type (e.g. HDD, | |
77 | SDD) for physical disks in the debug output, if applicable | |
78 | * Minor fix for 100GB physical disks, write "100GB" instead of "99GB" | |
79 | * SNMP: Use new features of OMSA 6.3.0 to display occupied and total | |
80 | slots in storage enclosures, if applicable. This information is not | |
81 | available with omreport and check_openmanage will not display this | |
82 | info in local mode. | |
83 | * SNMP: Added new processor IDs from the OMSA 6.3.0 MIBs | |
84 | * SNMP: Use connection tables in a proper way to determine controller | |
85 | and enclosure IDs, for use with physical disks and enclosure | |
86 | components (fan, temp sensors etc.). This fixes a long standing bug | |
87 | for servers with more than one controller, if checked via SNMP. | |
88 | * SNMP: Use the nexus ID as last resort to find the controller for | |
89 | physical disks. Workaround for older, broken OMSA versions. | |
90 | * SNMP: Identify enclosures (e.g. '2:0:0') properly so that the | |
91 | reporting with SNMP corresponds to the same report with omreport. | |
92 | * SNMP: added a couple of workarounds for pre-historic OMSA versions | |
93 | ||
94 | ||
9e56606a | 95 | 3.5.9 2010-06-29 |
96 | ------------------ | |
97 | ||
98 | * More fine-grained reporting of temperature warnings for enclosure | |
99 | temperature probes. | |
100 | * Max/min temperature limits for enclosure temp probes are reported in | |
101 | the debug output | |
102 | * Report enclosure temperature probes that are "Inactive" as ok | |
103 | * Don't try to print out the reading of enclosure temperature probes | |
104 | if the reading doesn't exist or is not an integer | |
105 | * Report enclosure EMMs that are "Not Installed" as ok, instead of | |
106 | critical | |
107 | * Corrected typo in the PNP4Nagios template | |
108 | ||
109 | ||
49958a98 | 110 | 3.5.8 2010-06-17 |
111 | ------------------ | |
112 | ||
113 | * Remove reporting of which controller a logical drive is "attached" | |
114 | to, since this information can't be reliably extracted via SNMP. | |
9e56606a | 115 | * Avoid collecting Lun ID via SNMP for virtual disks, we don't use it |
116 | * Report total memory and number of dimms in the ok output | |
117 | * Difference in reporting if amperage probes have discrete readings | |
118 | * Workaround for broken amperage probes | |
119 | * Added workaround for bad temperature probes that yields no reading | |
49958a98 | 120 | in SNMP mode |
9e56606a | 121 | * Get OMSA version via SNMP slightly more efficiently |
49958a98 | 122 | |
123 | ||
4723fc86 | 124 | 3.5.7 2010-03-19 |
88d0e634 | 125 | ------------------ |
126 | ||
127 | * Added robustness for received SNMP values that are not defined in | |
128 | the MIB. Instead of throwing a perl warning when this happens, the | |
129 | plugin will not report the undefined value. | |
130 | * Defined "Replacing" as a defined state for physical disks in SNMP | |
131 | mode, even though this state is not defined in the MIB. It is | |
132 | reported as such by omreport. | |
133 | * Physical disk brand/model is now reported when the state of the disk | |
134 | is "Rebuilding" or "Replacing". | |
4f5eca49 | 135 | * The state of a physical disk is reported in parentheses when |
88d0e634 | 136 | predictive failure is detected. It is useful to know if a disk is |
137 | online, offline, spare or even failed when predictive failure is | |
138 | reported. | |
139 | * Handling of physical disk predictive failure has been improved | |
140 | overall. | |
141 | * Refactoring of the perfdata code. In conformance with the plugin | |
142 | development guidelines, the UOM (unit of measure) previously | |
143 | reported in the perfdata output has been removed. | |
144 | * The -p or --perfdata option now | |
145 | takes an optional agrument 'minimal', which triggers shorter names | |
146 | for the perfomance data labels. This shortens the output and is a | |
147 | workaround for systems where the amount of output exceeds the 1024 | |
148 | char limit of NRPE. | |
149 | * The PNP4Nagios template has been updated. Users of check_openmanage | |
150 | and PNP4Nagios are advised to upgrade. This version of | |
151 | check_openmanage needs the new template. | |
88f7c874 | 152 | * Lots of other small improvements and updates. |
88d0e634 | 153 | |
154 | ||
77ae1787 | 155 | 3.5.6 2010-02-23 |
156 | ------------------ | |
157 | ||
158 | * New option '--use-get_table' is added as a workaround for SNMPv3 on | |
159 | Windows using net-snmp. This option will make check_openmanage use | |
160 | the Net::SNMP function get_table() instead of get_entries() to | |
161 | collect information via SNMP. | |
162 | * Include a blacklisting option 'ctrl_pdisk' which takes the | |
163 | controller number as argument. This blacklisting option only works | |
164 | with omreport and is a workaround for broken disk firmwares that | |
165 | contain illegal XML characters. These characters makes openmanage | |
166 | barf and exit with an error. Patch from Bas Couwenberg. | |
167 | * If the blacklisting keyword "all" is supplied for a component type, | |
168 | that component type is not checked at all, i.e. the commands are | |
169 | never executed. This will make check_openmanage execute faster if | |
170 | blacklisting is heavily used. | |
171 | * Option '--htmlinfo' now has a shorter equivalent '-I' | |
172 | * The option '--short-state' now has a shorter equivalent '-S' | |
173 | ||
174 | ||
a37a38e4 | 175 | 3.5.5 2010-01-22 |
75c0ce0f | 176 | ------------------ |
177 | ||
178 | * Fixed an SNMP bug where the plugin didn't handle OID indexes that | |
a37a38e4 | 179 | were not sequential. Thanks to Gianluca Varenni for reporting. |
75c0ce0f | 180 | * Fixed an SNMP bug when checking old hardware such as the PE 2650 and |
181 | PE 750. The controller id for physical drives were collected and | |
182 | displayed incorrectly. This release uses an additional OID to fetch | |
a37a38e4 | 183 | this info, which would otherwise be unavailable. Thanks to Gianluca |
184 | Varenni for reporting this bug. | |
185 | * Should use %snmp_probestatus, not %snmp_status when checking the | |
186 | status of voltage probes. Thanks to Ken McKinlay for a patch. | |
187 | * Fix when identifying blades via SNMP with very old OMSA | |
188 | versions. Patch from Ken McKinlay. | |
189 | * Better way of finding the ID of physical drives via SNMP | |
190 | ||
75c0ce0f | 191 | |
ba53af74 | 192 | 3.5.4 2010-01-13 |
193 | ------------------ | |
194 | ||
195 | * Added support for storport driver version for controllers, only | |
196 | applicable on servers running Windows. A new blacklisting keyword | |
197 | for suppressing storport driver messages was added. | |
879782a8 | 198 | * The "all" keyword in blacklisting is now case insensitive. |
ba53af74 | 199 | * More fine-grained reporting in the rare case where a controller |
07acfb60 | 200 | battery fails during learning and charging states. |
ba53af74 | 201 | * New improved way of reporting perl warnings during execution of the |
202 | plugin. | |
203 | ||
204 | ||
205 | 3.5.3 2009-12-17 | |
206 | ------------------ | |
207 | ||
208 | * Fix for path to omreport on Linux with OMSA 6.2.0 | |
209 | * A couple of other small fixes | |
210 | ||
211 | ||
cd34f3e7 | 212 | 3.5.2 2009-11-17 |
213 | ------------------ | |
214 | ||
215 | * Fix for undefined device name for logical drives (thanks to Pontus | |
216 | Fuchs for a patch) | |
217 | * Fixed a bug in the PNP4Nagios template, that prevented the template | |
218 | from working with PNP4Nagios 0.6. Thanks to the PNP4Nagios team for | |
219 | the fix. | |
220 | * Other small fixes | |
221 | ||
c9cde537 | 222 | 3.5.1 2009-10-22 |
d4c29457 | 223 | ------------------ |
224 | ||
225 | * CPU type, family etc. are now reported in case of a CPU failure (and | |
226 | in the debug output) | |
227 | * The debug output now reports Openmanage version and plugin version | |
228 | ||
229 | ||
c10216b6 | 230 | 3.5.0 2009-10-13 |
a4e4d852 | 231 | ------------------ |
232 | ||
233 | * New option '-a' or '--all' turns on checking of everything | |
234 | * The manual page (POD info) is removed from the script and is now in | |
235 | a separate file, to make check_openmanage fully ePN compatible | |
236 | * ePN is no longer disabled by default, check_openmanage no longer has | |
237 | an opinion on whether it should run under ePN or not | |
238 | * The '-m' or '--man' option is no longer available | |
02babec6 | 239 | * The option '-v' or '--verbose' is renamed to '-d' or '--debug', |
240 | which makes more sense wrt. its usage | |
a4e4d852 | 241 | * The '-g' or '--global' option is removed. Checking the global health |
242 | status is now default if applicable | |
243 | * Checking intrusion detection is now turned on by default | |
5cb5973b | 244 | * The obsolete option '--snmp' is removed |
a4e4d852 | 245 | * The option '--state' now has a shorter equivalent '-s' |
246 | * The basename stuff and options '--only-critical' and | |
247 | '--only-warning' are now replaced by an option '--only' | |
248 | * If plugin is run by Nagios, redirect stderr to stdout | |
02babec6 | 249 | * Added option '--omreport', that lets the user specify the full path |
250 | to the omreport binary | |
5cb5973b | 251 | * Added non-8bit-legacy default search paths for omreport.exe for |
252 | Windows boxen | |
253 | * Minor changes to the plugin output, for consistency | |
2fdf5f00 | 254 | * New blacklisting keyword 'bat_charge' disables warning messages |
ca98fb52 | 255 | related to controller cache battery charging. Thanks to Robert |
256 | Heinzmann for a patch. | |
ce662ba2 | 257 | * For blacklisting, the component ID kan now be "ALL", in which all |
258 | components of that type is blacklisted. | |
945f527c | 259 | * Man page is moved to manual section 8 |
260 | ||
a4e4d852 | 261 | |
262 | 3.4.9 2009-08-07 | |
263 | ------------------ | |
264 | ||
265 | * Fixed a bug that could cause errors and weird results when checking | |
266 | cooling devices (fans) via SNMP. Thanks to Ken McKinlay for spotting | |
267 | this bug and reporting it. | |
268 | ||
269 | 3.4.8 2009-07-31 | |
270 | ------------------ | |
271 | ||
272 | * For failed physical drives, check_openmanage will now output the | |
273 | drive's vendor, model and size in GB or TB. | |
274 | ||
275 | 3.4.7 2009-07-24 | |
276 | ------------------ | |
277 | ||
278 | * The -s|--snmp option was redundant and no longer does anything. SNMP | |
279 | is triggered automatically if the -H|--hostname option is | |
280 | present. The -s|--snmp option is kept for compatibility, but has no | |
281 | effect. | |
282 | ||
283 | 3.4.6 2009-07-07 | |
284 | ------------------ | |
285 | ||
286 | * Added support for performance data (temperatures) from attached | |
287 | storage enclosures such as the MD1000 | |
288 | ||
289 | 3.4.5 2009-06-22 | |
290 | ------------------ | |
291 | ||
292 | * Fixed a regression in the --htmlinfo option when it is not supplied | |
293 | with an argument | |
294 | ||
295 | 3.4.4 2009-06-22 | |
296 | ------------------ | |
297 | ||
298 | * New option --htmlinfo adds clickable HTML links in the plugin's | |
299 | output | |
300 | ||
301 | 3.4.3 2009-06-11 | |
302 | ------------------ | |
303 | ||
304 | * Fixed a regression bug in CPU and power supply reporting that only | |
305 | affects verbose output | |
306 | * If blacklisting is used, the global health check (via the --global | |
307 | option) is now negated. Checking the global health doesn't make | |
308 | sense when one or more components is blacklisted. Thanks to Rene | |
309 | Beaulieu for reporting this bug | |
310 | * The PNP4Nagios template is now included in the tarball and zip | |
311 | archive | |
312 | ||
313 | 3.4.2 2009-06-03 | |
314 | ------------------ | |
315 | ||
316 | * Improved memory error reporting, when using omreport | |
317 | * Collect performance data from pwrmonitoring (amperage probes) that | |
318 | were previously ignored when using omreport | |
319 | ||
320 | 3.4.1 2009-05-25 | |
321 | ------------------ | |
322 | ||
323 | * Improved memory error reporting, when using SNMP | |
324 | * Other small ehnancements | |
325 | ||
326 | 3.4.0 2009-05-25 | |
327 | ------------------ | |
328 | ||
329 | * The plugin is now compatible with the Nagios embedded Perl | |
330 | interpreter (ePN) in theory. However, the plugin will not not use | |
331 | ePN by default. We don't want any "accidents". | |
332 | * License is now GPLv3, previously only specified as "GPL" | |
333 | * New options --only-critical and --only-warning. With these options | |
334 | the plugin will only print critical or warning alerts, respectively. | |
335 | * Bugfixes and speed enhancements in the storage section, when | |
336 | checking enclosure components via omreport | |
337 | * The --okinfo option is now less verbose and more to the point | |
338 | * Lots of code refactoring for readability, maintainability and | |
339 | robustness | |
340 | ||
341 | 3.3.2 2009-05-05 | |
342 | ------------------ | |
343 | ||
344 | * Fixed a bug in the storage section, when checking controllers. This | |
345 | is an obscure bug that only manifests itself in the odd case where a | |
346 | server has multiple controllers, and one of the controllers are | |
347 | missing some of the OIDs, in which case these OIDs will be missing | |
348 | for the other controllers as well. The change is minor and only | |
349 | includes using get_table() instead of get_entries() to collect the | |
350 | SNMP result. Thanks to Stephan Bovet for reporting this bug. | |
351 | ||
352 | 3.3.1 2009-04-28 | |
353 | ------------------ | |
354 | ||
355 | * The --perfdata option can now optionally take an argument | |
356 | "multiline", which makes the plugin produce multiline performance | |
357 | data output in a Nagios 3.x way. Not really needed, but the plugin | |
358 | output is prettier. | |
359 | * Added comment within the 10 first lines to disable the nagios | |
360 | embedded perl (ePN) interpreter by default for Nagios 3.x | |
361 | * Improvements in the performance data output. Units are now included | |
362 | ||
363 | 3.3.0 2009-04-07 | |
364 | ------------------ | |
365 | ||
366 | * Added --global option, which turns on checking of everything. If | |
367 | used with SNMP, the global system health status is also probed, to | |
368 | protect the user against bugs in the plugin. If used with omreport, | |
369 | the overall chassis health is used. | |
370 | * Support for SNMP version 3 | |
371 | * New check added: esmhealth. This checks the overall health of the | |
372 | ESM log, i.e. the fill grade. More than 80% means a warning message | |
373 | * Fixed alert log reporting to use the same format as for the ESM log | |
374 | * Output messages are now sorted by severity | |
375 | * Minor changes in how out-of-date controller firmware/driver is | |
376 | reported | |
377 | * Code refactoring and cleanup | |
378 | ||
379 | 3.2.7 2009-03-29 | |
380 | ------------------ | |
381 | ||
382 | * Use "omreport about" to collect OMSA version. Slightly faster than | |
383 | "omreport system version". This should give a small speedup in | |
384 | certain configurations | |
385 | * Fixed typo in output when a logical drive is rebuilding. Thanks to | |
386 | Andreas Olsson for reporting | |
387 | * Improved reporting of ESM log content | |
388 | * Added omreport.sh as alternate omreport path | |
389 | * Lots of other small fixes and enhancements | |
390 | ||
391 | Plus: A few changes to make the plugin work with old PowerEdge models | |
392 | (e.g. 2550, 2450) and/or old OMSA versions (e.g. version 4.5): | |
393 | ||
394 | * Use the chassisModelName OID to determine if SNMP works (instead of | |
395 | BaseboardType) | |
396 | * No longer require a response when checking baseboard type via | |
397 | SNMP. If there is no response, we assume that we're not dealing with | |
398 | a blade server | |
399 | ||
400 | Thanks to Christian McHugh for help with testing and debugging this | |
401 | stuff | |
402 | ||
403 | 3.2.6 2009-03-05 | |
404 | ------------------ | |
405 | ||
406 | * Use 'omreport system operatingsystem' to collect OS info, instead of | |
407 | 'omreport system' version which is incredibly slow. This should speed | |
408 | things up in certain configurations. | |
409 | * A few speedups, don't collect information that isn't needed | |
410 | * Man page fixes | |
411 | ||
412 | 3.2.5 2009-02-24 | |
413 | ------------------ | |
414 | ||
415 | * New option --linebreak to specify the separator between line in case | |
416 | of multiline output | |
417 | * Added support for 64bit Windows. Thanks to Patrick Hemmen for a patch | |
418 | * [Patrick Hemmen] Added install.bat for Windows installation | |
419 | * [Patrick Hemmen] Improvements on install.sh. Will now install in | |
420 | /usr/lib64 for x86_64 | |
421 | * RPMs are now architecture dependent, because of different libdir | |
422 | ||
423 | 3.2.4 2009-02-17 | |
424 | ------------------ | |
425 | ||
426 | * New option -o|--ok-info to display extra information when everything | |
427 | is ok. The plugin can now display storage firmware and driver info, | |
428 | DRAC and BMC firmware, and OMSA version | |
429 | * Support for setting custom minimum temperature thresholds via the | |
430 | -c|--critical and -w|--warning options | |
431 | * Better and more detailed temperature error reporting | |
432 | * Bugfix in the amperage report (including performance data). The | |
433 | plugin now takes into account the correct unit and measurement for | |
434 | amperage probes (other than watts) | |
435 | * New option --port lets the user specify the remote SNMP port number | |
436 | ||
437 | 3.2.3 2009-02-09 | |
438 | ------------------ | |
439 | ||
440 | * Regression fix: Use the older Processor Device SNMP OIDs for older | |
441 | PowerEdge models, that don't have the new Processor Device Status | |
442 | OIDs. Thanks to Nicole Hähnel for reporting this bug. | |
443 | * Default output (when there are no alerts) now shows RAC firmware, | |
444 | BMC firmware, info about controllers and enclosures (firmware, | |
445 | driver). | |
446 | ||
447 | 3.2.2 2009-02-03 | |
448 | ------------------ | |
449 | ||
450 | * Regression fix: Ignore unoccupied CPU slots with SNMP probing. This | |
451 | fixes a bug introduced in versjon 3.2.1, which would output | |
452 | something like this if one or more CPU slots were empty: CPU 1 needs | |
453 | attention () | |
454 | ||
455 | 3.2.1 2009-02-03 | |
456 | ------------------ | |
457 | ||
458 | * Use Processor Device Status Table OIDs instead of Processor Device | |
459 | Table when checking CPUs via SNMP | |
460 | * Bugfix: don't report throttled CPUs as warnings when checking via | |
461 | SNMP (same as for checking locally) | |
462 | ||
463 | 3.2.0 2009-01-27 | |
464 | ------------------ | |
465 | ||
466 | * New options --state and --short-state for displaying service state | |
467 | along with the alert | |
468 | * Lots of small fixes for code readability and maintainability | |
469 | ||
470 | 3.1.1 2009-01-12 | |
471 | ------------------ | |
472 | ||
473 | * Support for running natively on Windows (using omreport.exe). Thanks | |
474 | to Peter Jestico for a patch. | |
475 | * Support for compiled Windows version, i.e. check_openmanage.exe is | |
476 | now a legal script name. | |
477 | * Exit with error if script basename is illegal/unknown | |
478 | * Various small fixes | |
479 | ||
480 | 3.1.0 2008-12-26 | |
481 | ------------------ | |
482 | ||
483 | * Use of alternate basenames for checking only one class of components | |
484 | * Added support for checking the ESM log via SNMP | |
485 | * Code refactoring for robustness and maintainability | |
486 | * Numerous small fixes and enhancements | |
487 | * Added install script in distribution tarball | |
488 | ||
489 | 3.0.2 2008-12-20 | |
490 | ------------------ | |
491 | ||
492 | * The script no longer aborts if it can't get system information via | |
493 | SNMP. Give a warning instead, as this is not a critical error | |
494 | * Increased robustness when checking controllers | |
495 | ||
496 | 3.0.1 2008-12-11 | |
497 | ------------------ | |
498 | ||
499 | * Man page fix in the 'check' section. Thanks to Ansgar Dahlen for | |
500 | reporting this. | |
501 | * Allow invalid command error from 'omreport chassis pwrmonitoring' | |
502 | * Various small fixes | |
503 | ||
504 | 3.0.0 2008-12-04 | |
505 | ------------------ | |
506 | ||
507 | * Use unique IDs for storage components with regard to blacklisting, | |
508 | which means that the blacklisting API has changed | |
509 | * Added checks for storage components: connectors (channels), | |
510 | enclosures, enclosure fans, enclosure power supplies, enclosure | |
511 | temperature probes and enclosure management modules (EMMs) | |
512 | * Improved verbose output | |
513 | * New option -t|--timeout for setting the plugin timeout | |
514 | * New option -w|--warning for setting custom temperature warning | |
515 | thresholds | |
516 | * New option -c|--critical for setting custom temperature critical | |
517 | thresholds | |
518 | * Option --check can no longer be specified in its short form (-c) | |
519 | * Code cleanup and improvements | |
520 | ||
521 | 2.1.1 2008-11-24 | |
522 | ------------------ | |
523 | ||
524 | * The workaround for the OMSA bug introduced in OMSA 5.5.0 didn't take | |
525 | multiple controllers into account. This has been fixed. | |
526 | ||
527 | 2.1.0 2008-11-19 | |
528 | ------------------ | |
529 | ||
530 | * New option -i|--info prefixes all alerts with the service tag | |
531 | * New option -e|--extinfo gives and extra line of output in case of an | |
532 | alert (model and service tag) | |
533 | * New option --postmsg lets the user specify a post message string, | |
534 | with info such as model, service tag etc. | |
535 | * Options -b|--blacklist and -c|--check can now be specified multiple | |
536 | times (actually quite useful) | |
537 | ||
538 | 2.0.9 2008-11-17 | |
539 | ------------------ | |
540 | ||
541 | * Slightly improved output for alerts on logical drives (vdisks) | |
542 | * Now shows a rebuilding physical disk as a warning, as this is | |
543 | usually accompanied by a degraded vdisk. Previous versions didn't | |
544 | show this at all (omreport classifies it as "OK"). | |
545 | ||
546 | 2.0.8 2008-11-14 | |
547 | ------------------ | |
548 | ||
549 | * Slightly improved output for charging controller batteries | |
550 | ||
551 | 2.0.7 2008-11-12 | |
552 | ------------------ | |
553 | ||
554 | * Bugfix for reporting physical drives with predictive failure (both | |
555 | via NRPE and SNMP) | |
556 | ||
557 | 2.0.6 2008-10-30 | |
558 | ------------------ | |
559 | ||
560 | * Fix bug in option handling (ambiguous options) | |
561 | * Slightly improved output if checking the storage subsystem is turned | |
562 | off | |
563 | * Don't complain if there are no logical drives. This is OK. Thanks to | |
564 | Jamie Henderson for reporting this | |
565 | ||
566 | 2.0.5 2008-10-29 | |
567 | ------------------ | |
568 | ||
569 | * Fix bug in SNMP status level table | |
570 | ||
571 | 2.0.4 2008-10-29 | |
572 | ------------------ | |
573 | ||
574 | * Added workaround for a BUG introduced in OpenManage 5.5.0. OM | |
575 | sometimes adds a newline in the controller driver version name, | |
576 | which leads to problems parsing the output. Thanks to Hiren Patel | |
577 | for bringing this to my attention. | |
578 | ||
579 | 2.0.3 2008-10-28 | |
580 | ------------------ | |
581 | ||
582 | * (snmp) Improved handling of cases where OM is not working properly | |
583 | ||
584 | 2.0.2 2008-10-27 | |
585 | ------------------ | |
586 | ||
587 | * Fixed issue where controller number for physical disks can't be | |
588 | established via SNMP (now identifies as controller no. -1) | |
589 | ||
590 | 2.0.1 2008-10-23 | |
591 | ------------------ | |
592 | ||
593 | * Correctly identifies and reports error condition in which OpenManage | |
594 | has stopped working (it happens) | |
595 | ||
596 | 2.0.0 2008-10-23 | |
597 | ------------------ | |
598 | ||
599 | * SNMP support | |
600 | * Same options for checking, blacklisting etc. supported with SNMP | |
601 | * Same output with SNMP as with NRPE | |
602 | ||
603 | 1.2.1 2008-09-25 | |
604 | ------------------ | |
605 | ||
606 | * Collects performance data if the option '-p' or '--perfdata' is | |
607 | supplied. | |
608 | * New blacklisting directives ctrl_fw and ctrl_driver | |
609 | added. Suppresses the "special" warning messages concerning outdated | |
610 | controller firmware and driver. Useful if you can't or won't | |
611 | upgrade. | |
612 | ||
613 | 1.1.2 2008-08-06 | |
614 | ------------------ | |
615 | ||
616 | * Fix getting system model and serial number for newer blades | |
617 | ||
618 | 1.1.1 2008-08-06 | |
619 | ------------------ | |
620 | ||
621 | * Three new checks added: | |
622 | - System battery probes (typical CMOS battery). Newer poweredge | |
623 | models have these | |
624 | - Power consumption monitoring (if the server supports it) | |
625 | - ESM log, with same functionality as the alert log check. Disabled | |
626 | by default. | |
627 | ||
628 | 1.1.0 2008-08-04 | |
629 | ------------------ | |
630 | ||
631 | * Internal refactoring: use ssv-formatted output from openmanage, | |
632 | resulting in slightly faster execution and increased robustness. | |
633 | * If /usr/bin/omreport doesn't exist, try | |
634 | /opt/dell/srvadmin/oma/bin/omreport. | |
635 | * Allow for no instrumented/redundant power supplies. Needed on | |
636 | low-end poweredge models and blades. | |
637 | ||
638 | 1.0.3 2008-07-25 | |
639 | ------------------ | |
640 | ||
641 | * Openmanage reports non-critical warning about throttled CPUs on new | |
642 | hardware models. Most og us use ondemand CPU frequency scaling (with | |
643 | throttled CPUs as a result). This specific non-critical warning (CPU | |
644 | Throttled) is ignored from now on. | |
645 | * Remove superfluous Celcius sign when reporting temperatures. | |
646 | ||
647 | 1.0.2 2008-07-25 | |
648 | ------------------ | |
649 | ||
650 | * Accommodate blade systems with no fans or powersupplies, i.e. accept | |
651 | errors from omreport when trying to check fans or powersupplies on | |
652 | blade servers. | |
653 | * Accommodate newer hardware with slightly different omreport | |
654 | options. Use the newer options if they exist. Not really necessary | |
655 | yet, but deprecated options may be removed in future versions of | |
656 | Dell OpenManage. | |
657 | ||
658 | 1.0.1 2008-07-18 | |
659 | ------------------ | |
660 | ||
661 | * When everything is OK, check_openmanage now outputs the same info as | |
662 | Gerhard Lausser's excellent check_hpasm plugin does for HP servers: | |
663 | ||
664 | OK - System: 'poweredge 2850', S/N: 'XXXXXXX', ROM: 'A06 | |
665 | 10/03/2006', hardware working fine, 2 logical drives, 4 physical | |
666 | drives | |
667 | ||
668 | 1.0.0 2008-07-15 | |
669 | ------------------ | |
670 | ||
671 | * Initial release |