b53ed7ea 3# pod2man -s 8 -r "`./check_openmanage -V | head -n 1`" -c 'Nagios plugin' check_openmanage.pod check_openmanage.8
669797e1 4#
5# $Id$
6
7=head1 NAME
8
9check_openmanage - Nagios plugin for checking the hardware status on
10 Dell servers running OpenManage
11
12=head1 SYNOPSIS
13
14check_openmanage [I<OPTION>]...
b0f29cfc 15
6a3615ec 16check_openmanage -H I<hostname> [I<OPTION>]...
669797e1 17
18=head1 DESCRIPTION
19
20check_openmanage is a plugin for Nagios which checks the hardware
21health of Dell servers running OpenManage Server Administrator
22(OMSA). The plugin checks the health of the storage subsystem, power
23supplies, memory modules, temperature probes etc., and gives an alert
24if any of the components are faulty or operate outside normal
25parameters.
26
27check_openmanage is designed to be used by either locally (using NRPE
28or similar) or remotely (using SNMP). In either mode, the output is
29(nearly) the same. Note that checking the alert log is not supported
30in SNMP mode.
31
32=head1 GENERAL OPTIONS
33
34=over 4
35
36=item -t, --timeout I<SECONDS>
37
38The number of seconds after which the plugin will abort. Default
39timeout is 30 seconds if the option is not present.
40
aca136f2 41=item -p, --perfdata [I<multline> or I<minimal>]
669797e1 42
43Collect performance data. Performance data collected include
c1c1118a 44temperatures (in Celsius) and fan speeds (in rpm). On systems that
aca136f2 45support it, power consumption is also collected (in Watts). This
46option takes one of two arguments, both of which are optional.
47
48If the argument C<minimal> is specified, the plugin will use shorter
49names for the performance data labels, e.g. C<t0> instead of
50C<temp_0_system_board_ambient>. This can be used as a workaround in
51cases where the plugin output needs shortening, for example if the
521024 character limit of NRPE is reached.
669797e1 53
54If given the argument C<multiline>, the plugin will output the
55performance data on multiple lines, for Nagios 3.x and above.
56
57=item -w, --warning I<STRING> or I<FILE>
58
59Override the machine-default temperature warning thresholds. Syntax is
60C<id1=max[/min],id2=max[/min],...>. The following example sets warning
61limits to max 50C for probe 0, and max 45C and min 10C for probe 1:
62
63check_openmanage -w 0=50,1=45/10
64
65The minimum limit can be omitted, if desired. Most often, you are only
66interested in setting the maximum thresholds.
67
68This parameter can be either a string with the limits, or a file
69containing the limits string. The option can be specified multiple
70times.
71
b0f29cfc 72NOTE: This option should only be used to narrow the field of OK
73temperatures wrt. the OMSA defaults. To expand the field of OK
74temperatures, increase the OMSA thresholds. See the plugin web page
75for more information.
76
669797e1 77=item -c, --critical I<STRING> or I<FILE>
78
79Override the machine-default temperature critical thresholds. Syntax
80and behaviour is the same as for warning thresholds described above.
81
82=item -o, --ok-info I<NUMBER>
83
84This option lets you define how much output you want the plugin to
85give when everything is OK, i.e. the verbosity level. The default
86value is 0 (one line of output). The output levels are cumulative.
87
88=over 4
89
90=item B<0>
91
92- Only one line (default)
93
94=item B<1>
95
96- BIOS and firmware info on a separate line
97
98=item B<2>
99
100- Storage controller and enclosure info on separate lines
101
102=item B<3>
103
104- OMSA version on separate line
105
106=back
107
108The reason that OMSA version is separated from the rest is that
109finding it requires running a really slow omreport command, when the
110plugin is run locally via NRPE.
111
71d7d930 112=item --omreport I<OMREPORT PATH>
113
114Specify full path to omreport, if it is not installed in any of the
115regular places. Usually this option is only needed on Windows, if
116omreport is not installed on the C: drive.
117
669797e1 118=item -i, --info
119
120Prefix any alerts with the service tag.
121
122=item -e, --extinfo
123
124Display a short summary of system information (model and service tag)
125in case of an alert.
126
d27881e0 127=item -I, --htmlinfo [I<CODE>]
669797e1 128
129Using this option will make the servicetag and model name into
130clickable HTML links in the output. The model name link will point to
131the official Dell documentation for that model, while the servicetag
132link will point to a website containing support info for that
133particular server.
134
135This option takes an optional argument, which should be your country
136code or C<me> for the middle east. If the country code is omitted the
137servicetag link will still work, but it will not be speficic for your
138country or area. Example for Germany:
139
140 check_openmanage --htmlinfo de
141
142If this option is used together with either the I<--extinfo> or
143I<--info> options, it is particularly useful. Only the most common
144country codes is supported at this time.
145
146=item --postmsg I<STRING> or I<FILE>
147
148User specified post message. Useful for displaying arbitrary or
149various system information at the end of alerts. The argument is
150either a string with the message, or a file containing that
151string. You can control the format with the following interpreted
152sequences:
153
154=over 4
155
156=item B<%m>
157
158System model
159
160=item B<%s>
161
162Service tag
163
164=item B<%b>
165
166BIOS version
167
168=item B<%d>
169
170BIOS release date
171
172=item B<%o>
173
174Operating system name
175
176=item B<%r>
177
178Operating system release
179
180=item B<%p>
181
182Number of physical drives
183
184=item B<%l>
185
186Number of logical drives
187
188=item B<%n>
189
190Line break. Will be a regular line break if run from a TTY, else an
191HTML line break.
192
193=item B<%%>
194
195A literal C<%>
196
197=back
198
199=item -s, --state
200
201Prefix each alert with its corresponding service state (i.e. warning,
202critical etc.). This is useful in case of several alerts from the same
203monitored system.
204
d27881e0 205=item -S, --short-state
669797e1 206
207Same as the B<--state> option above, except that the state is
208abbreviated to a single letter (W=warning, C=critical etc.).
209
fb90e271 210=item --linebreak I<STRING>
669797e1 211
212check_openmanage will sometimes report more than one line, e.g. if
213there are several alerts. If the script has a TTY, it will use regular
214linebreaks. If not (which is the case with NRPE) it will use HTML
215linebreaks. Sometimes it can be useful to control what the plugin uses
216as a line separator, and this option provides that control.
217
218The argument is the exact string to be used as the line
219separator. There are two exceptions, i.e. two keywords that translates
220to the following:
221
222=over 4
223
224=item B<REG>
225
226Regular linebreaks, i.e. "\n".
227
228=item B<HTML>
229
230HTML linebreaks, i.e. "<br/>".
231
232=back
233
234This is a rather special option that is normally not needed. The
235default behaviour should be sufficient for most users.
236
237=item -d, --debug
238
239Debug output. Will report status on everything, even if status is
240ok. Blacklisted or unchecked components are ignored (i.e. no output).
241
242NOTE: This option is intended for diagnostics and debugging purposes
243only. Do not use this option from within Nagios, i.e. in the Nagios
244config.
245
246=item -h, --help
247
248Display help text.
249
250=item -V, --version
251
252Display version info.
253
254=back
255
256=head1 SNMP OPTIONS
257
258=over 4
259
260=item -H, --hostname I<HOSTNAME>
261
262The transport address of the destination SNMP device. Using this
263option triggers SNMP mode.
264
265=item -P, --protocol I<PROTOCOL>
266
267SNMP protocol version. This option is optional and expects a digit
268(i.e. C<1>, C<2> or C<3>) to define the SNMP version. The default is
269C<2>, i.e. SNMP version 2c.
270
271=item -C, --community I<COMMUNITY>
272
273This option expects a string that is to be used as the SNMP community
274name when using SNMP version 1 or 2c. By default the community name
275is set to C<public> if the option is not present.
276
277=item --port I<PORT>
278
279SNMP port of the remote (monitored) system. Defaults to the well-known
280SNMP port 161.
281
282=item -U, --username I<SECURITYNAME>
283
284[SNMPv3] The User-based Security Model (USM) used by SNMPv3 requires
285that a securityName be specified. This option is required when using
286SNMP version 3, and expects a string 1 to 32 octets in lenght.
287
288=item --authpassword I<PASSWORD>, --authkey I<KEY>
289
290[SNMPv3] By default a securityLevel of C<noAuthNoPriv> is assumed. If
291the --authpassword option is specified, the securityLevel becomes
292C<authNoPriv>. The --authpassword option expects a string which is at
293least 1 octet in length as argument.
294
295Optionally, instead of the --authpassword option, the --authkey option
296can be used so that a plain text password does not have to be
297specified in a script. The --authkey option expects a hexadecimal
298string produced by localizing the password with the
299authoritativeEngineID for the specific destination device. The
300C<snmpkey> utility included with the Net::SNMP distribution can be
301used to create the hexadecimal string (see L<snmpkey>).
302
303=item --authprotocol I<ALGORITHM>
304
305[SNMPv3] Two different hash algorithms are defined by SNMPv3 which can
306be used by the Security Model for authentication. These algorithms are
307HMAC-MD5-96 C<MD5> (RFC 1321) and HMAC-SHA-96 C<SHA-1> (NIST FIPS PUB
308180-1). The default algorithm used by the plugin is HMAC-MD5-96. This
309behavior can be changed by using this option. The option expects
310either the string C<md5> or C<sha> to be passed as argument to modify
311the hash algorithm.
312
313=item --privpassword I<PASSWORD>, --privkey I<KEY>
314
315[SNMPv3] By specifying the options --privkey or --privpassword, the
316securityLevel associated with the object becomes
317C<authPriv>. According to SNMPv3, privacy requires the use of
318authentication. Therefore, if either of these two options are present
319and the --authkey or --authpassword arguments are missing, the
320creation of the object fails. The --privkey and --privpassword
321options expect the same input as the --authkey and --authpassword
322options respectively.
323
324=item --privprotocol I<ALGORITHM>
325
326[SNMPv3] The User-based Security Model described in RFC 3414 defines a
327single encryption protocol to be used for privacy. This protocol,
328CBC-DES C<DES> (NIST FIPS PUB 46-1), is used by default or if the
329string C<des> is passed to the --privprotocol option. The Net::SNMP
330module also supports RFC 3826 which describes the use of
331CFB128-AES-128 C<AES> (NIST FIPS PUB 197) in the USM. The AES
332encryption protocol can be selected by passing C<aes> or C<aes128> to
333the --privprotocol option.
334
335One of the following arguments are required: des, aes, aes128, 3des,
3363desde
337
606e084f 338=item --use-get_table
339
340This option exists as a workaround when using check_openmanage with
341SNMPv3 on Windows with net-snmp. Using this option will make
342check_openmanage use the Net::SNMP function get_table() instead of
343get_entries() while fetching values via SNMP. The latter is faster and
344is the default.
345
669797e1 346=back
347
348=head1 BLACKLISTING
349
350=over 4
351
352=item -b, --blacklist I<STRING> or I<FILE>
353
354Blacklist missing and/or failed components, if you do not plan to fix
355them. The parameter is either the blacklist string, or a file (that
356may or may not exist) containing the string. The blacklist string
357contains component names with component IDs separated by slash
358(/). Blacklisted components are left unchecked.
359
360TIP: Use the option C<-d> (or C<--debug>) to get the blacklist ID for
361devices. The ID is listed in a separate column in the debug output.
362
0b6ba9c9 363NOTE: If blacklisting is in effect, the global health of the system is
364not checked.
669797e1 365
366=over 9
367
368=item B<Syntax:>
369
370component1=id1[,id2,...]/component2=id1[,id2,...]/...
371
02bf599a 372The ID part can also be C<all>, in which all components of that type
0b6ba9c9 373is blacklisted.
374
669797e1 375=item B<Example:>
376
02bf599a 377check_openmanage -b ps=0/fan=3,5/pdisk=1:0:0:1/ctrl_driver=all
669797e1 378
379=back
380
0b6ba9c9 381In the example we blacklist powersupply 0, fans 3 and 5, physical disk
3821:0:0:1, and warnings about out-of-date drivers for all
383controllers. Legal component names include:
669797e1 384
385=over 8
386
387=item B<ctrl>
388
0b6ba9c9 389Storage controller. Note that if a controller is blacklisted, all
390components on that controller (such as physical and logical drives)
391are blacklisted as well.
669797e1 392
393=item B<ctrl_fw>
394
395Suppress the special warning message about old controller
396firmware. Use this if you can not or will not upgrade the firmware.
397
398=item B<ctrl_driver>
399
400Suppress the special warning message about old controller driver.
401Particularly useful on systems where you can not upgrade the driver.
402
8dd8083c 403=item B<ctrl_stdr>
404
405Suppress the special warning message about old Storport driver on
406Windows.
407
d27881e0 408=item B<ctrl_pdisk>
409
410This blacklisting keyword exists as a possible workaround for physical
411drives with bad firmware which makes Openmanage choke. It takes the
412controller number as argument. Use this option to blacklist all
413physical drives on a specific controller. This blacklisting keyword is
414only available in local mode, i.e. not with SNMP.
415
669797e1 416=item B<pdisk>
417
418Physical disk.
419
420=item B<vdisk>
421
422Logical drive (virtual disk)
423
424=item B<bat>
425
426Controller cache battery
427
7b02bc55 428=item B<bat_charge>
429
430Ignore warnings related to the controller cache battery charging
7031b02a 431cycle, which happens approximately every 40 days on Dell servers. Note
432that using this blacklist keyword makes check_openmanage ignore
433non-critical cache battery errors.
7b02bc55 434
669797e1 435=item B<conn>
436
437Connector (channel)
438
439=item B<encl>
440
441Enclosure
442
443=item B<encl_fan>
444
445Enclosure fan
446
447=item B<encl_ps>
448
449Enclosure power supply
450
451=item B<encl_temp>
452
453Enclosure temperature probe
454
455=item B<encl_emm>
456
457Enclosure management module (EMM)
458
459=item B<dimm>
460
461Memory module
462
463=item B<fan>
464
465Fan
466
467=item B<ps>
468
469Powersupply
470
471=item B<temp>
472
473Temperature sensor
474
475=item B<cpu>
476
477Processor (CPU)
478
479=item B<volt>
480
481Voltage probe
482
483=item B<bp>
484
485System battery
486
600bd61b 487=item B<amp>
669797e1 488
489Amperage probe (power consumption monitoring)
490
491=item B<intr>
492
493Intrusion sensor
494
495=back
496
497=back
498
499=head1 CHECK CONTROL
500
501=over 4
502
503=item --only I<KEYWORD>
504
505This option can be specifed once and expects a keyword. The different
506keywords and the behaviour of check_openmanage is described below.
507
508=over 4
509
510=item B<critical>
511
512Print only critical alerts. With this option any warning alerts are
513suppressed.
514
515=item B<warning>
516
517Print only warning alerts. With this option any critical alerts are
518suppressed.
519
520=item B<chassis>
521
522Check all chassis components and nothing else.
523
524=item B<storage>
525
526Only check storage
527
528=item B<memory>
529
530Only check memory modules
531
532=item B<fans>
533
534Only check fans
535
536=item B<power>
537
538Only check power supplies
539
540=item B<temp>
541
542Only check temperatures
543
544=item B<cpu>
545
546Only check processors
547
548=item B<voltage>
549
550Only check voltage probes
551
552=item B<batteries>
553
554Only check batteries
555
556=item B<amperage>
557
558Only check power usage
559
560=item B<intrusion>
561
562Only check chassis intrusion
563
564=item B<esmhealth>
565
566Only check ESM log overall health, i.e. fill grade
567
568=item B<esmlog>
569
570Only check the event log (ESM) content
571
572=item B<alertlog>
573
574Only check the alert log content
575
576=back
577
578=item --check I<STRING> or I<FILE>
579
580This parameter allows you to adjust which components that should be
581checked at all. This is a rougher approach than blacklisting, which
582require that you specify component id or index. The parameter should
583be either a string containing the adjustments, or a file containing
584the string. No errors are raised if the file does not exist.
585
586Note: This option is ignored with alternate basenames.
587
588=over 9
589
590=item B<Example:>
591
592check_openmanage --check storage=0,intrusion=1
593
594=back
595
596Legal values are described below, along with the default value.
597
598=over 4
599
600=item B<storage>
601
602Check storage subsystem (controllers, disks etc.). Default: ON
603
604=item B<memory>
605
606Check memory (dimms). Default: ON
607
608=item B<fans>
609
610Check chassis fans. Default: ON
611
612=item B<power>
613
614Check power supplies. Default: ON
615
616=item B<temp>
617
618Check temperature sensors. Default: ON
619
620=item B<cpu>
621
622Check CPUs. Default: ON
623
624=item B<voltage>
625
626Check voltage sensors. Default: ON
627
628=item B<batteries>
629
630Check system batteries. Default: ON
631
632=item B<amperage>
633
634Check amperage probes. Default: ON
635
636=item B<intrusion>
637
638Check chassis intrusion. Default: ON
639
640=item B<esmhealth>
641
642Check the ESM log health, i.e. fill grade. Default: ON
643
644=item B<esmlog>
645
646Check the ESM log content. Default: OFF
647
648=item B<alertlog>
649
650Check the alert log content. Default: OFF
651
652=back
653
654=back
655
c105a16f 656=item --no-storage
657
658Turn off storage checking. This is an alias for C<--check storage=0>.
659
660=back
661
669797e1 662=head1 DIAGNOSTICS
663
664The option C<--debug> (or C<-d>) can be specified to display all
665monitored components.
666
667=head1 DEPENDENCIES
668
669If SNMP is requested, the perl module Net::SNMP is
670required. Otherwise, only a regular perl distribution is required to
671run the script. On the target (monitored) system, Dell Openmanage
672Server Administrator (OMSA) must be installed and running.
673
674=head1 EXIT STATUS
675
676If no errors are discovered, a value of 0 (OK) is returned. An exit
677value of 1 (WARNING) signifies one or more non-critical errors, while
6782 (CRITICAL) signifies one or more critical errors.
679
680The exit value 3 (UNKNOWN) is reserved for errors within the script,
681or errors getting values from Dell OMSA.
682
683=head1 AUTHOR
684
685Written by Trond H. Amundsen <t.h.amundsen@usit.uio.no>
686
687=head1 BUGS AND LIMITATIONS
688
689Storage info is not collected or checked on very old PowerEdge models
690and/or old OMSA versions, due to limitations in OMSA. The overall
691support on those models/versions by this plugin is not well tested.
692
693=head1 INCOMPATIBILITIES
694
695The plugin should work with the Nagios embedded perl interpreter
696(ePN). However, this is not thoroughly tested.
697
698=head1 REPORTING BUGS
699
700Report bugs to <t.h.amundsen@usit.uio.no>
701
702=head1 LICENSE AND COPYRIGHT
703
704This program is free software: you can redistribute it and/or modify
705it under the terms of the GNU General Public License as published by
706the Free Software Foundation, either version 3 of the License, or (at
707your option) any later version.
708
709This program is distributed in the hope that it will be useful, but
710WITHOUT ANY WARRANTY; without even the implied warranty of
711MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
712General Public License for more details.
713
714You should have received a copy of the GNU General Public License
715along with this program. If not, see L<http://www.gnu.org/licenses/>.
716
717=head1 SEE ALSO