1 3.6.5   2011-02-08
2 ------------------
3
4 * Fix counting of components when blacklisting is used. Components
5   should be counted even if blacklisted
6 * Added some unsupported vdisk types to the list. The OMSA MIB
7   identifies these, but lists them as unsupported.
8 * Added option '-B' or '--show-blacklist' to show any blacklistings in
9   the OK output
10 * Fixed a bug for checking voltage probes, if the reading is missing
11   via SNMP.
12
13 3.6.4   2011-01-04
14 ------------------
15
16 * Added more robustness wrt. values from OMSA obtained via SNMP, to
17   avoid internal errors where non-important values are missing.
18
19 3.6.3   2010-12-13
20 ------------------
21
22 * A few compatibility fixes for OMSA 6.4.0 were added.
23
24 3.6.2   2010-11-25
25 ------------------
26
27 * Added support for IPv6 when checking via SNMP. IPv6 can be turned on
28   with the option '-6' or '--ipv6'. The default is IPv4 if the option
29   is not present.
30 * Added support for TCP when checking vis SNMP. The option '--tcp' can
31   be used to turn on TCP. The default transport protocol is UDP if the
32   option is not present.
33 * The mode of operation (local or SNMP) is shown in the debug
34   output. If SNMP is used, the debug output will also show the SNMP
35   protocol version, IP version and transport protocol (UDP or TCP).
36 * Amperage probe status via SNMP is of type "probe status", not
37   regular status. This has been fixed.
38 * Massive overall robustness improvements to handle OMSA bugs where
39   some information from OMSA is missing.
40 * Memory module enumeration via SNMP changed somewhat to reflect
41   enumeration provided by omreport. This ensures that the plugin's
42   output is identical in SNMP or local mode wrt. dimms IDs.
43 * Fan enumeration via SNMP changed somewhat to reflect enumeration
44   provided by omreport. This ensures that the plugin's output is
45   identical in SNMP or local mode wrt. fan IDs.
46
47 3.6.1   2010-11-02
48 ------------------
49
50 * Included new check for SD cards. Newer servers such as the R710 can
51   have SD cards installed, these should be monitored. The SD card
52   check is on by default. A new blacklisting keyword 'sd' has been
53   added. The SD card check can be turned off with '--check sdcard=0'.
54 * Handle special cases where power monitoring capability is disabled
55   due to non-redundant and/or non-instrumented power supplies.
56 * For physical disks probed via SNMP, check that values for vendor,
57   product ID and capacity is available before attempting to display
58   those values.
59 * If a physical disk is in sufficiently bad condition, the vendor
60   field reported by OMSA may be empty. The plugin now handles this
61   situation without throwing an internal error.
62
63
64 3.6.0   2010-08-30
65 ------------------
66
67 * Storage is no longer allowed to be absent. If the plugin doesn't
68   find a storage controller, it will give an alert. For diskless
69   systems or servers without a Dell controller that OMSA recognizes
70   you will now have to specify '--no-storage' or '--check storage=0'
71   to work around this.
72 * Report the system revision (if applicable) wherever the model name
73   is printed. E.g. "PowerEdge 2950 III" instead of "PowerEdge 2950".
74 * Small change in search path for omreport: The new location for OMSA
75   6.2.0 and later on Linux will be attempted first.
76 * Small bugfix for the '--check' parameter, if the argument is a
77   filename. The file could not contain a linebreak, this has been
78   fixed.
79 * Added an option '--no-storage', which is equivalent to the general
80   option '--check storage=0'.
81
82
83 3.5.10  2010-07-14
84 ------------------
85
86 * If a physical disk is a hot spare, display this information in
87   the debug output
88 * Report the bus protocol (e.g. SAS, SATA) and media type (e.g. HDD,
89   SDD) for physical disks in the debug output, if applicable
90 * Minor fix for 100GB physical disks, write "100GB" instead of "99GB"
91 * SNMP: Use new features of OMSA 6.3.0 to display occupied and total
92   slots in storage enclosures, if applicable. This information is not
93   available with omreport and check_openmanage will not display this
94   info in local mode.
95 * SNMP: Added new processor IDs from the OMSA 6.3.0 MIBs
96 * SNMP: Use connection tables in a proper way to determine controller
97   and enclosure IDs, for use with physical disks and enclosure
98   components (fan, temp sensors etc.). This fixes a long standing bug
99   for servers with more than one controller, if checked via SNMP.
100 * SNMP: Use the nexus ID as last resort to find the controller for
101   physical disks. Workaround for older, broken OMSA versions.
102 * SNMP: Identify enclosures (e.g. '2:0:0') properly so that the
103   reporting with SNMP corresponds to the same report with omreport.
104 * SNMP: added a couple of workarounds for pre-historic OMSA versions
105
106
107 3.5.9   2010-06-29
108 ------------------
109
110 * More fine-grained reporting of temperature warnings for enclosure
111   temperature probes.
112 * Max/min temperature limits for enclosure temp probes are reported in
113   the debug output
114 * Report enclosure temperature probes that are "Inactive" as ok
115 * Don't try to print out the reading of enclosure temperature probes
116   if the reading doesn't exist or is not an integer
117 * Report enclosure EMMs that are "Not Installed" as ok, instead of
118   critical
119 * Corrected typo in the PNP4Nagios template
120
121
122 3.5.8   2010-06-17
123 ------------------
124
125 * Remove reporting of which controller a logical drive is "attached"
126   to, since this information can't be reliably extracted via SNMP.
127 * Avoid collecting Lun ID via SNMP for virtual disks, we don't use it
128 * Report total memory and number of dimms in the ok output
129 * Difference in reporting if amperage probes have discrete readings
130 * Workaround for broken amperage probes
131 * Added workaround for bad temperature probes that yields no reading
132   in SNMP mode
133 * Get OMSA version via SNMP slightly more efficiently
134
135
136 3.5.7   2010-03-19
137 ------------------
138
139 * Added robustness for received SNMP values that are not defined in
140   the MIB. Instead of throwing a perl warning when this happens, the
141   plugin will not report the undefined value.
142 * Defined "Replacing" as a defined state for physical disks in SNMP
143   mode, even though this state is not defined in the MIB. It is
144   reported as such by omreport.
145 * Physical disk brand/model is now reported when the state of the disk
146   is "Rebuilding" or "Replacing".
147 * The state of a physical disk is reported in parentheses when
148   predictive failure is detected. It is useful to know if a disk is
149   online, offline, spare or even failed when predictive failure is
150   reported.
151 * Handling of physical disk predictive failure has been improved
152   overall.
153 * Refactoring of the perfdata code. In conformance with the plugin
154   development guidelines, the UOM (unit of measure) previously
155   reported in the perfdata output has been removed.
156 * The -p or --perfdata option now
157   takes an optional agrument 'minimal', which triggers shorter names
158   for the perfomance data labels. This shortens the output and is a
159   workaround for systems where the amount of output exceeds the 1024
160   char limit of NRPE.
161 * The PNP4Nagios template has been updated. Users of check_openmanage
162   and PNP4Nagios are advised to upgrade. This version of
163   check_openmanage needs the new template.
164 * Lots of other small improvements and updates.
165
166
167 3.5.6   2010-02-23
168 ------------------
169
170 * New option '--use-get_table' is added as a workaround for SNMPv3 on
171   Windows using net-snmp. This option will make check_openmanage use
172   the Net::SNMP function get_table() instead of get_entries() to
173   collect information via SNMP.
174 * Include a blacklisting option 'ctrl_pdisk' which takes the
175   controller number as argument. This blacklisting option only works
176   with omreport and is a workaround for broken disk firmwares that
177   contain illegal XML characters. These characters makes openmanage
178   barf and exit with an error. Patch from Bas Couwenberg.
179 * If the blacklisting keyword "all" is supplied for a component type,
180   that component type is not checked at all, i.e. the commands are
181   never executed. This will make check_openmanage execute faster if
182   blacklisting is heavily used.
183 * Option '--htmlinfo' now has a shorter equivalent '-I'
184 * The option '--short-state' now has a shorter equivalent '-S'
185
186
187 3.5.5   2010-01-22
188 ------------------
189
190 * Fixed an SNMP bug where the plugin didn't handle OID indexes that
191   were not sequential. Thanks to Gianluca Varenni for reporting.
192 * Fixed an SNMP bug when checking old hardware such as the PE 2650 and
193   PE 750. The controller id for physical drives were collected and
194   displayed incorrectly. This release uses an additional OID to fetch
195   this info, which would otherwise be unavailable. Thanks to Gianluca
196   Varenni for reporting this bug.
197 * Should use %snmp_probestatus, not %snmp_status when checking the
198   status of voltage probes. Thanks to Ken McKinlay for a patch.
199 * Fix when identifying blades via SNMP with very old OMSA
200   versions. Patch from Ken McKinlay.
201 * Better way of finding the ID of physical drives via SNMP
202
203
204 3.5.4   2010-01-13
205 ------------------
206
207 * Added support for storport driver version for controllers, only
208   applicable on servers running Windows.  A new blacklisting keyword
209   for suppressing storport driver messages was added.
210 * The "all" keyword in blacklisting is now case insensitive.
211 * More fine-grained reporting in the rare case where a controller
212   battery fails during learning and charging states.
213 * New improved way of reporting perl warnings during execution of the
214   plugin.
215
216
217 3.5.3   2009-12-17
218 ------------------
219
220 * Fix for path to omreport on Linux with OMSA 6.2.0
221 * A couple of other small fixes
222
223
224 3.5.2   2009-11-17
225 ------------------
226
227 * Fix for undefined device name for logical drives (thanks to Pontus
228   Fuchs for a patch)
229 * Fixed a bug in the PNP4Nagios template, that prevented the template
230   from working with PNP4Nagios 0.6. Thanks to the PNP4Nagios team for
231   the fix.
232 * Other small fixes
233
234 3.5.1   2009-10-22
235 ------------------
236
237 * CPU type, family etc. are now reported in case of a CPU failure (and
238   in the debug output)
239 * The debug output now reports Openmanage version and plugin version
240
241
242 3.5.0   2009-10-13
243 ------------------
244
245 * New option '-a' or '--all' turns on checking of everything
246 * The manual page (POD info) is removed from the script and is now in
247   a separate file, to make check_openmanage fully ePN compatible
248 * ePN is no longer disabled by default, check_openmanage no longer has
249   an opinion on whether it should run under ePN or not
250 * The '-m' or '--man' option is no longer available
251 * The option '-v' or '--verbose' is renamed to '-d' or '--debug',
252   which makes more sense wrt. its usage
253 * The '-g' or '--global' option is removed. Checking the global health
254   status is now default if applicable
255 * Checking intrusion detection is now turned on by default
256 * The obsolete option '--snmp' is removed
257 * The option '--state' now has a shorter equivalent '-s'
258 * The basename stuff and options '--only-critical' and
259   '--only-warning' are now replaced by an option '--only'
260 * If plugin is run by Nagios, redirect stderr to stdout
261 * Added option '--omreport', that lets the user specify the full path
262   to the omreport binary
263 * Added non-8bit-legacy default search paths for omreport.exe for
264   Windows boxen
265 * Minor changes to the plugin output, for consistency
266 * New blacklisting keyword 'bat_charge' disables warning messages
267   related to controller cache battery charging. Thanks to Robert
268   Heinzmann for a patch.
269 * For blacklisting, the component ID kan now be "ALL", in which all
270   components of that type is blacklisted.
271 * Man page is moved to manual section 8
272
273
274 3.4.9   2009-08-07
275 ------------------
276
277 * Fixed a bug that could cause errors and weird results when checking
278   cooling devices (fans) via SNMP. Thanks to Ken McKinlay for spotting
279   this bug and reporting it.
280
281 3.4.8   2009-07-31
282 ------------------
283
284 * For failed physical drives, check_openmanage will now output the
285   drive's vendor, model and size in GB or TB.
286
287 3.4.7   2009-07-24
288 ------------------
289
290 * The -s|--snmp option was redundant and no longer does anything. SNMP
291   is triggered automatically if the -H|--hostname option is
292   present. The -s|--snmp option is kept for compatibility, but has no
293   effect.
294
295 3.4.6   2009-07-07
296 ------------------
297
298 * Added support for performance data (temperatures) from attached
299   storage enclosures such as the MD1000
300
301 3.4.5   2009-06-22
302 ------------------
303
304 * Fixed a regression in the --htmlinfo option when it is not supplied
305   with an argument
306
307 3.4.4   2009-06-22
308 ------------------
309
310 * New option --htmlinfo adds clickable HTML links in the plugin's
311   output
312
313 3.4.3   2009-06-11
314 ------------------
315
316 * Fixed a regression bug in CPU and power supply reporting that only
317   affects verbose output
318 * If blacklisting is used, the global health check (via the --global
319   option) is now negated. Checking the global health doesn't make
320   sense when one or more components is blacklisted. Thanks to Rene
321   Beaulieu for reporting this bug
322 * The PNP4Nagios template is now included in the tarball and zip
323   archive
324
325 3.4.2   2009-06-03
326 ------------------
327
328 * Improved memory error reporting, when using omreport
329 * Collect performance data from pwrmonitoring (amperage probes) that
330   were previously ignored when using omreport
331
332 3.4.1   2009-05-25
333 ------------------
334
335 * Improved memory error reporting, when using SNMP
336 * Other small ehnancements
337
338 3.4.0   2009-05-25
339 ------------------
340
341 * The plugin is now compatible with the Nagios embedded Perl
342   interpreter (ePN) in theory. However, the plugin will not not use
343   ePN by default. We don't want any "accidents".
344 * License is now GPLv3, previously only specified as "GPL"
345 * New options --only-critical and --only-warning. With these options
346   the plugin will only print critical or warning alerts, respectively.
347 * Bugfixes and speed enhancements in the storage section, when
348   checking enclosure components via omreport
349 * The --okinfo option is now less verbose and more to the point
350 * Lots of code refactoring for readability, maintainability and
351   robustness
352
353 3.3.2   2009-05-05
354 ------------------
355
356 * Fixed a bug in the storage section, when checking controllers. This
357   is an obscure bug that only manifests itself in the odd case where a
358   server has multiple controllers, and one of the controllers are
359   missing some of the OIDs, in which case these OIDs will be missing
360   for the other controllers as well. The change is minor and only
361   includes using get_table() instead of get_entries() to collect the
362   SNMP result. Thanks to Stephan Bovet for reporting this bug.
363
364 3.3.1   2009-04-28
365 ------------------
366
367 * The --perfdata option can now optionally take an argument
368   "multiline", which makes the plugin produce multiline performance
369   data output in a Nagios 3.x way. Not really needed, but the plugin
370   output is prettier.
371 * Added comment within the 10 first lines to disable the nagios
372   embedded perl (ePN) interpreter by default for Nagios 3.x
373 * Improvements in the performance data output. Units are now included
374
375 3.3.0   2009-04-07
376 ------------------
377
378 * Added --global option, which turns on checking of everything. If
379   used with SNMP, the global system health status is also probed, to
380   protect the user against bugs in the plugin. If used with omreport,
381   the overall chassis health is used.
382 * Support for SNMP version 3
383 * New check added: esmhealth. This checks the overall health of the
384   ESM log, i.e. the fill grade. More than 80% means a warning message
385 * Fixed alert log reporting to use the same format as for the ESM log
386 * Output messages are now sorted by severity
387 * Minor changes in how out-of-date controller firmware/driver is
388   reported
389 * Code refactoring and cleanup
390
391 3.2.7   2009-03-29
392 ------------------
393
394 * Use "omreport about" to collect OMSA version. Slightly faster than
395   "omreport system version". This should give a small speedup in
396   certain configurations
397 * Fixed typo in output when a logical drive is rebuilding. Thanks to
398   Andreas Olsson for reporting
399 * Improved reporting of ESM log content
400 * Added omreport.sh as alternate omreport path
401 * Lots of other small fixes and enhancements
402
403 Plus: A few changes to make the plugin work with old PowerEdge models
404 (e.g. 2550, 2450) and/or old OMSA versions (e.g. version 4.5):
405
406 * Use the chassisModelName OID to determine if SNMP works (instead of
407   BaseboardType)
408 * No longer require a response when checking baseboard type via
409   SNMP. If there is no response, we assume that we're not dealing with
410   a blade server
411
412 Thanks to Christian McHugh for help with testing and debugging this
413 stuff
414
415 3.2.6   2009-03-05
416 ------------------
417
418 * Use 'omreport system operatingsystem' to collect OS info, instead of
419   'omreport system' version which is incredibly slow. This should speed
420   things up in certain configurations.
421 * A few speedups, don't collect information that isn't needed
422 * Man page fixes
423
424 3.2.5   2009-02-24
425 ------------------
426
427 * New option --linebreak to specify the separator between line in case
428   of multiline output
429 * Added support for 64bit Windows. Thanks to Patrick Hemmen for a patch
430 * [Patrick Hemmen] Added install.bat for Windows installation
431 * [Patrick Hemmen] Improvements on install.sh. Will now install in
432   /usr/lib64 for x86_64
433 * RPMs are now architecture dependent, because of different libdir
434
435 3.2.4   2009-02-17
436 ------------------
437
438 * New option -o|--ok-info to display extra information when everything
439   is ok. The plugin can now display storage firmware and driver info,
440   DRAC and BMC firmware, and OMSA version
441 * Support for setting custom minimum temperature thresholds via the
442   -c|--critical and -w|--warning options
443 * Better and more detailed temperature error reporting
444 * Bugfix in the amperage report (including performance data). The
445   plugin now takes into account the correct unit and measurement for
446   amperage probes (other than watts)
447 * New option --port lets the user specify the remote SNMP port number
448
449 3.2.3   2009-02-09
450 ------------------
451
452 * Regression fix: Use the older Processor Device SNMP OIDs for older
453   PowerEdge models, that don't have the new Processor Device Status
454   OIDs. Thanks to Nicole Hähnel for reporting this bug.
455 * Default output (when there are no alerts) now shows RAC firmware,
456   BMC firmware, info about controllers and enclosures (firmware,
457   driver).
458
459 3.2.2   2009-02-03
460 ------------------
461
462 * Regression fix: Ignore unoccupied CPU slots with SNMP probing. This
463   fixes a bug introduced in versjon 3.2.1, which would output
464   something like this if one or more CPU slots were empty: CPU 1 needs
465   attention ()
466
467 3.2.1   2009-02-03
468 ------------------
469
470 * Use Processor Device Status Table OIDs instead of Processor Device
471   Table when checking CPUs via SNMP
472 * Bugfix: don't report throttled CPUs as warnings when checking via
473   SNMP (same as for checking locally)
474
475 3.2.0   2009-01-27
476 ------------------
477
478 * New options --state and --short-state for displaying service state
479   along with the alert
480 * Lots of small fixes for code readability and maintainability
481
482 3.1.1   2009-01-12
483 ------------------
484
485 * Support for running natively on Windows (using omreport.exe). Thanks
486   to Peter Jestico for a patch.
487 * Support for compiled Windows version, i.e. check_openmanage.exe is
488   now a legal script name.
489 * Exit with error if script basename is illegal/unknown
490 * Various small fixes
491
492 3.1.0   2008-12-26
493 ------------------
494
495 * Use of alternate basenames for checking only one class of components
496 * Added support for checking the ESM log via SNMP
497 * Code refactoring for robustness and maintainability
498 * Numerous small fixes and enhancements
499 * Added install script in distribution tarball
500
501 3.0.2   2008-12-20
502 ------------------
503
504 * The script no longer aborts if it can't get system information via
505   SNMP. Give a warning instead, as this is not a critical error
506 * Increased robustness when checking controllers
507
508 3.0.1   2008-12-11
509 ------------------
510
511 * Man page fix in the 'check' section. Thanks to Ansgar Dahlen for
512   reporting this.
513 * Allow invalid command error from 'omreport chassis pwrmonitoring'
514 * Various small fixes
515
516 3.0.0   2008-12-04
517 ------------------
518
519 * Use unique IDs for storage components with regard to blacklisting,
520   which means that the blacklisting API has changed
521 * Added checks for storage components: connectors (channels),
522   enclosures, enclosure fans, enclosure power supplies, enclosure
523   temperature probes and enclosure management modules (EMMs)
524 * Improved verbose output
525 * New option -t|--timeout for setting the plugin timeout
526 * New option -w|--warning for setting custom temperature warning
527   thresholds
528 * New option -c|--critical for setting custom temperature critical
529   thresholds
530 * Option --check can no longer be specified in its short form (-c)
531 * Code cleanup and improvements
532
533 2.1.1   2008-11-24
534 ------------------
535
536 * The workaround for the OMSA bug introduced in OMSA 5.5.0 didn't take
537   multiple controllers into account. This has been fixed.
538
539 2.1.0   2008-11-19
540 ------------------
541
542 * New option -i|--info prefixes all alerts with the service tag
543 * New option -e|--extinfo gives and extra line of output in case of an
544   alert (model and service tag)
545 * New option --postmsg lets the user specify a post message string,
546   with info such as model, service tag etc.
547 * Options -b|--blacklist and -c|--check can now be specified multiple
548   times (actually quite useful)
549
550 2.0.9   2008-11-17
551 ------------------
552
553 * Slightly improved output for alerts on logical drives (vdisks)
554 * Now shows a rebuilding physical disk as a warning, as this is
555   usually accompanied by a degraded vdisk. Previous versions didn't
556   show this at all (omreport classifies it as "OK").
557
558 2.0.8   2008-11-14
559 ------------------
560
561 * Slightly improved output for charging controller batteries
562
563 2.0.7   2008-11-12
564 ------------------
565
566 * Bugfix for reporting physical drives with predictive failure (both
567   via NRPE and SNMP)
568
569 2.0.6   2008-10-30
570 ------------------
571
572 * Fix bug in option handling (ambiguous options)
573 * Slightly improved output if checking the storage subsystem is turned
574   off
575 * Don't complain if there are no logical drives. This is OK. Thanks to
576   Jamie Henderson for reporting this
577
578 2.0.5   2008-10-29
579 ------------------
580
581 * Fix bug in SNMP status level table
582
583 2.0.4   2008-10-29
584 ------------------
585
586 * Added workaround for a BUG introduced in OpenManage 5.5.0. OM
587   sometimes adds a newline in the controller driver version name,
588   which leads to problems parsing the output. Thanks to Hiren Patel
589   for bringing this to my attention.
590
591 2.0.3   2008-10-28
592 ------------------
593
594 * (snmp) Improved handling of cases where OM is not working properly
595
596 2.0.2   2008-10-27
597 ------------------
598
599 * Fixed issue where controller number for physical disks can't be
600   established via SNMP (now identifies as controller no. -1)
601
602 2.0.1   2008-10-23
603 ------------------
604
605 * Correctly identifies and reports error condition in which OpenManage
606   has stopped working (it happens)
607
608 2.0.0   2008-10-23
609 ------------------
610
611 * SNMP support
612 * Same options for checking, blacklisting etc. supported with SNMP
613 * Same output with SNMP as with NRPE
614
615 1.2.1   2008-09-25
616 ------------------
617
618 * Collects performance data if the option '-p' or '--perfdata' is
619   supplied.
620 * New blacklisting directives ctrl_fw and ctrl_driver
621   added. Suppresses the "special" warning messages concerning outdated
622   controller firmware and driver. Useful if you can't or won't
623   upgrade.
624
625 1.1.2   2008-08-06
626 ------------------
627
628 * Fix getting system model and serial number for newer blades
629
630 1.1.1   2008-08-06
631 ------------------
632
633 * Three new checks added:
634   - System battery probes (typical CMOS battery). Newer poweredge
635     models have these
636   - Power consumption monitoring (if the server supports it)
637   - ESM log, with same functionality as the alert log check. Disabled
638     by default.
639
640 1.1.0   2008-08-04
641 ------------------
642
643 * Internal refactoring: use ssv-formatted output from openmanage,
644   resulting in slightly faster execution and increased robustness.
645 * If /usr/bin/omreport doesn't exist, try
646   /opt/dell/srvadmin/oma/bin/omreport.
647 * Allow for no instrumented/redundant power supplies. Needed on
648   low-end poweredge models and blades.
649
650 1.0.3   2008-07-25
651 ------------------
652
653 * Openmanage reports non-critical warning about throttled CPUs on new
654   hardware models. Most og us use ondemand CPU frequency scaling (with
655   throttled CPUs as a result). This specific non-critical warning (CPU
656   Throttled) is ignored from now on.
657 * Remove superfluous Celcius sign when reporting temperatures.
658
659 1.0.2   2008-07-25
660 ------------------
661
662 * Accommodate blade systems with no fans or powersupplies, i.e. accept
663   errors from omreport when trying to check fans or powersupplies on
664   blade servers.
665 * Accommodate newer hardware with slightly different omreport
666   options. Use the newer options if they exist. Not really necessary
667   yet, but deprecated options may be removed in future versions of
668   Dell OpenManage.
669
670 1.0.1   2008-07-18
671 ------------------
672
673 * When everything is OK, check_openmanage now outputs the same info as
674   Gerhard Lausser's excellent check_hpasm plugin does for HP servers:
675
676   OK - System: 'poweredge 2850', S/N: 'XXXXXXX', ROM: 'A06
677   10/03/2006', hardware working fine, 2 logical drives, 4 physical
678   drives
679
680 1.0.0   2008-07-15