]> git.uio.no Git - check_openmanage.git/blob - CHANGES
bugfix
[check_openmanage.git] / CHANGES
1 3.5.2   2009-11-17
2 ------------------
3
4 * Fix for undefined device name for logical drives (thanks to Pontus
5   Fuchs for a patch)
6 * Fixed a bug in the PNP4Nagios template, that prevented the template
7   from working with PNP4Nagios 0.6. Thanks to the PNP4Nagios team for
8   the fix.
9 * Other small fixes
10
11 3.5.1   2009-10-22
12 ------------------
13
14 * CPU type, family etc. are now reported in case of a CPU failure (and
15   in the debug output)
16 * The debug output now reports Openmanage version and plugin version
17
18
19 3.5.0   2009-10-13
20 ------------------
21
22 * New option '-a' or '--all' turns on checking of everything
23 * The manual page (POD info) is removed from the script and is now in
24   a separate file, to make check_openmanage fully ePN compatible
25 * ePN is no longer disabled by default, check_openmanage no longer has
26   an opinion on whether it should run under ePN or not
27 * The '-m' or '--man' option is no longer available
28 * The option '-v' or '--verbose' is renamed to '-d' or '--debug',
29   which makes more sense wrt. its usage
30 * The '-g' or '--global' option is removed. Checking the global health
31   status is now default if applicable
32 * Checking intrusion detection is now turned on by default
33 * The obsolete option '--snmp' is removed
34 * The option '--state' now has a shorter equivalent '-s'
35 * The basename stuff and options '--only-critical' and
36   '--only-warning' are now replaced by an option '--only'
37 * If plugin is run by Nagios, redirect stderr to stdout
38 * Added option '--omreport', that lets the user specify the full path
39   to the omreport binary
40 * Added non-8bit-legacy default search paths for omreport.exe for
41   Windows boxen
42 * Minor changes to the plugin output, for consistency
43 * New blacklisting keyword 'bat_charge' disables warning messages
44   related to controller cache battery charging. Thanks to Robert
45   Heinzmann for a patch.
46 * For blacklisting, the component ID kan now be "ALL", in which all
47   components of that type is blacklisted.
48 * Man page is moved to manual section 8
49
50
51 3.4.9   2009-08-07
52 ------------------
53
54 * Fixed a bug that could cause errors and weird results when checking
55   cooling devices (fans) via SNMP. Thanks to Ken McKinlay for spotting
56   this bug and reporting it.
57
58 3.4.8   2009-07-31
59 ------------------
60
61 * For failed physical drives, check_openmanage will now output the
62   drive's vendor, model and size in GB or TB.
63
64 3.4.7   2009-07-24
65 ------------------
66
67 * The -s|--snmp option was redundant and no longer does anything. SNMP
68   is triggered automatically if the -H|--hostname option is
69   present. The -s|--snmp option is kept for compatibility, but has no
70   effect.
71
72 3.4.6   2009-07-07
73 ------------------
74
75 * Added support for performance data (temperatures) from attached
76   storage enclosures such as the MD1000
77
78 3.4.5   2009-06-22
79 ------------------
80
81 * Fixed a regression in the --htmlinfo option when it is not supplied
82   with an argument
83
84 3.4.4   2009-06-22
85 ------------------
86
87 * New option --htmlinfo adds clickable HTML links in the plugin's
88   output
89
90 3.4.3   2009-06-11
91 ------------------
92
93 * Fixed a regression bug in CPU and power supply reporting that only
94   affects verbose output
95 * If blacklisting is used, the global health check (via the --global
96   option) is now negated. Checking the global health doesn't make
97   sense when one or more components is blacklisted. Thanks to Rene
98   Beaulieu for reporting this bug
99 * The PNP4Nagios template is now included in the tarball and zip
100   archive
101
102 3.4.2   2009-06-03
103 ------------------
104
105 * Improved memory error reporting, when using omreport
106 * Collect performance data from pwrmonitoring (amperage probes) that
107   were previously ignored when using omreport
108
109 3.4.1   2009-05-25
110 ------------------
111
112 * Improved memory error reporting, when using SNMP
113 * Other small ehnancements
114
115 3.4.0   2009-05-25
116 ------------------
117
118 * The plugin is now compatible with the Nagios embedded Perl
119   interpreter (ePN) in theory. However, the plugin will not not use
120   ePN by default. We don't want any "accidents".
121 * License is now GPLv3, previously only specified as "GPL"
122 * New options --only-critical and --only-warning. With these options
123   the plugin will only print critical or warning alerts, respectively.
124 * Bugfixes and speed enhancements in the storage section, when
125   checking enclosure components via omreport
126 * The --okinfo option is now less verbose and more to the point
127 * Lots of code refactoring for readability, maintainability and
128   robustness
129
130 3.3.2   2009-05-05
131 ------------------
132
133 * Fixed a bug in the storage section, when checking controllers. This
134   is an obscure bug that only manifests itself in the odd case where a
135   server has multiple controllers, and one of the controllers are
136   missing some of the OIDs, in which case these OIDs will be missing
137   for the other controllers as well. The change is minor and only
138   includes using get_table() instead of get_entries() to collect the
139   SNMP result. Thanks to Stephan Bovet for reporting this bug.
140
141 3.3.1   2009-04-28
142 ------------------
143
144 * The --perfdata option can now optionally take an argument
145   "multiline", which makes the plugin produce multiline performance
146   data output in a Nagios 3.x way. Not really needed, but the plugin
147   output is prettier.
148 * Added comment within the 10 first lines to disable the nagios
149   embedded perl (ePN) interpreter by default for Nagios 3.x
150 * Improvements in the performance data output. Units are now included
151
152 3.3.0   2009-04-07
153 ------------------
154
155 * Added --global option, which turns on checking of everything. If
156   used with SNMP, the global system health status is also probed, to
157   protect the user against bugs in the plugin. If used with omreport,
158   the overall chassis health is used.
159 * Support for SNMP version 3
160 * New check added: esmhealth. This checks the overall health of the
161   ESM log, i.e. the fill grade. More than 80% means a warning message
162 * Fixed alert log reporting to use the same format as for the ESM log
163 * Output messages are now sorted by severity
164 * Minor changes in how out-of-date controller firmware/driver is
165   reported
166 * Code refactoring and cleanup
167
168 3.2.7   2009-03-29
169 ------------------
170
171 * Use "omreport about" to collect OMSA version. Slightly faster than
172   "omreport system version". This should give a small speedup in
173   certain configurations
174 * Fixed typo in output when a logical drive is rebuilding. Thanks to
175   Andreas Olsson for reporting
176 * Improved reporting of ESM log content
177 * Added omreport.sh as alternate omreport path
178 * Lots of other small fixes and enhancements
179
180 Plus: A few changes to make the plugin work with old PowerEdge models
181 (e.g. 2550, 2450) and/or old OMSA versions (e.g. version 4.5):
182
183 * Use the chassisModelName OID to determine if SNMP works (instead of
184   BaseboardType)
185 * No longer require a response when checking baseboard type via
186   SNMP. If there is no response, we assume that we're not dealing with
187   a blade server
188
189 Thanks to Christian McHugh for help with testing and debugging this
190 stuff
191
192 3.2.6   2009-03-05
193 ------------------
194
195 * Use 'omreport system operatingsystem' to collect OS info, instead of
196   'omreport system' version which is incredibly slow. This should speed
197   things up in certain configurations.
198 * A few speedups, don't collect information that isn't needed
199 * Man page fixes
200
201 3.2.5   2009-02-24
202 ------------------
203
204 * New option --linebreak to specify the separator between line in case
205   of multiline output
206 * Added support for 64bit Windows. Thanks to Patrick Hemmen for a patch
207 * [Patrick Hemmen] Added install.bat for Windows installation
208 * [Patrick Hemmen] Improvements on install.sh. Will now install in
209   /usr/lib64 for x86_64
210 * RPMs are now architecture dependent, because of different libdir
211
212 3.2.4   2009-02-17
213 ------------------
214
215 * New option -o|--ok-info to display extra information when everything
216   is ok. The plugin can now display storage firmware and driver info,
217   DRAC and BMC firmware, and OMSA version
218 * Support for setting custom minimum temperature thresholds via the
219   -c|--critical and -w|--warning options
220 * Better and more detailed temperature error reporting
221 * Bugfix in the amperage report (including performance data). The
222   plugin now takes into account the correct unit and measurement for
223   amperage probes (other than watts)
224 * New option --port lets the user specify the remote SNMP port number
225
226 3.2.3   2009-02-09
227 ------------------
228
229 * Regression fix: Use the older Processor Device SNMP OIDs for older
230   PowerEdge models, that don't have the new Processor Device Status
231   OIDs. Thanks to Nicole Hähnel for reporting this bug.
232 * Default output (when there are no alerts) now shows RAC firmware,
233   BMC firmware, info about controllers and enclosures (firmware,
234   driver).
235
236 3.2.2   2009-02-03
237 ------------------
238
239 * Regression fix: Ignore unoccupied CPU slots with SNMP probing. This
240   fixes a bug introduced in versjon 3.2.1, which would output
241   something like this if one or more CPU slots were empty: CPU 1 needs
242   attention ()
243
244 3.2.1   2009-02-03
245 ------------------
246
247 * Use Processor Device Status Table OIDs instead of Processor Device
248   Table when checking CPUs via SNMP
249 * Bugfix: don't report throttled CPUs as warnings when checking via
250   SNMP (same as for checking locally)
251
252 3.2.0   2009-01-27
253 ------------------
254
255 * New options --state and --short-state for displaying service state
256   along with the alert
257 * Lots of small fixes for code readability and maintainability
258
259 3.1.1   2009-01-12
260 ------------------
261
262 * Support for running natively on Windows (using omreport.exe). Thanks
263   to Peter Jestico for a patch.
264 * Support for compiled Windows version, i.e. check_openmanage.exe is
265   now a legal script name.
266 * Exit with error if script basename is illegal/unknown
267 * Various small fixes
268
269 3.1.0   2008-12-26
270 ------------------
271
272 * Use of alternate basenames for checking only one class of components
273 * Added support for checking the ESM log via SNMP
274 * Code refactoring for robustness and maintainability
275 * Numerous small fixes and enhancements
276 * Added install script in distribution tarball
277
278 3.0.2   2008-12-20
279 ------------------
280
281 * The script no longer aborts if it can't get system information via
282   SNMP. Give a warning instead, as this is not a critical error
283 * Increased robustness when checking controllers
284
285 3.0.1   2008-12-11
286 ------------------
287
288 * Man page fix in the 'check' section. Thanks to Ansgar Dahlen for
289   reporting this.
290 * Allow invalid command error from 'omreport chassis pwrmonitoring'
291 * Various small fixes
292
293 3.0.0   2008-12-04
294 ------------------
295
296 * Use unique IDs for storage components with regard to blacklisting,
297   which means that the blacklisting API has changed
298 * Added checks for storage components: connectors (channels),
299   enclosures, enclosure fans, enclosure power supplies, enclosure
300   temperature probes and enclosure management modules (EMMs)
301 * Improved verbose output
302 * New option -t|--timeout for setting the plugin timeout
303 * New option -w|--warning for setting custom temperature warning
304   thresholds
305 * New option -c|--critical for setting custom temperature critical
306   thresholds
307 * Option --check can no longer be specified in its short form (-c)
308 * Code cleanup and improvements
309
310 2.1.1   2008-11-24
311 ------------------
312
313 * The workaround for the OMSA bug introduced in OMSA 5.5.0 didn't take
314   multiple controllers into account. This has been fixed.
315
316 2.1.0   2008-11-19
317 ------------------
318
319 * New option -i|--info prefixes all alerts with the service tag
320 * New option -e|--extinfo gives and extra line of output in case of an
321   alert (model and service tag)
322 * New option --postmsg lets the user specify a post message string,
323   with info such as model, service tag etc.
324 * Options -b|--blacklist and -c|--check can now be specified multiple
325   times (actually quite useful)
326
327 2.0.9   2008-11-17
328 ------------------
329
330 * Slightly improved output for alerts on logical drives (vdisks)
331 * Now shows a rebuilding physical disk as a warning, as this is
332   usually accompanied by a degraded vdisk. Previous versions didn't
333   show this at all (omreport classifies it as "OK").
334
335 2.0.8   2008-11-14
336 ------------------
337
338 * Slightly improved output for charging controller batteries
339
340 2.0.7   2008-11-12
341 ------------------
342
343 * Bugfix for reporting physical drives with predictive failure (both
344   via NRPE and SNMP)
345
346 2.0.6   2008-10-30
347 ------------------
348
349 * Fix bug in option handling (ambiguous options)
350 * Slightly improved output if checking the storage subsystem is turned
351   off
352 * Don't complain if there are no logical drives. This is OK. Thanks to
353   Jamie Henderson for reporting this
354
355 2.0.5   2008-10-29
356 ------------------
357
358 * Fix bug in SNMP status level table
359
360 2.0.4   2008-10-29
361 ------------------
362
363 * Added workaround for a BUG introduced in OpenManage 5.5.0. OM
364   sometimes adds a newline in the controller driver version name,
365   which leads to problems parsing the output. Thanks to Hiren Patel
366   for bringing this to my attention.
367
368 2.0.3   2008-10-28
369 ------------------
370
371 * (snmp) Improved handling of cases where OM is not working properly
372
373 2.0.2   2008-10-27
374 ------------------
375
376 * Fixed issue where controller number for physical disks can't be
377   established via SNMP (now identifies as controller no. -1)
378
379 2.0.1   2008-10-23
380 ------------------
381
382 * Correctly identifies and reports error condition in which OpenManage
383   has stopped working (it happens)
384
385 2.0.0   2008-10-23
386 ------------------
387
388 * SNMP support
389 * Same options for checking, blacklisting etc. supported with SNMP
390 * Same output with SNMP as with NRPE
391
392 1.2.1   2008-09-25
393 ------------------
394
395 * Collects performance data if the option '-p' or '--perfdata' is
396   supplied.
397 * New blacklisting directives ctrl_fw and ctrl_driver
398   added. Suppresses the "special" warning messages concerning outdated
399   controller firmware and driver. Useful if you can't or won't
400   upgrade.
401
402 1.1.2   2008-08-06
403 ------------------
404
405 * Fix getting system model and serial number for newer blades
406
407 1.1.1   2008-08-06
408 ------------------
409
410 * Three new checks added:
411   - System battery probes (typical CMOS battery). Newer poweredge
412     models have these
413   - Power consumption monitoring (if the server supports it)
414   - ESM log, with same functionality as the alert log check. Disabled
415     by default.
416
417 1.1.0   2008-08-04
418 ------------------
419
420 * Internal refactoring: use ssv-formatted output from openmanage,
421   resulting in slightly faster execution and increased robustness.
422 * If /usr/bin/omreport doesn't exist, try
423   /opt/dell/srvadmin/oma/bin/omreport.
424 * Allow for no instrumented/redundant power supplies. Needed on
425   low-end poweredge models and blades.
426
427 1.0.3   2008-07-25
428 ------------------
429
430 * Openmanage reports non-critical warning about throttled CPUs on new
431   hardware models. Most og us use ondemand CPU frequency scaling (with
432   throttled CPUs as a result). This specific non-critical warning (CPU
433   Throttled) is ignored from now on.
434 * Remove superfluous Celcius sign when reporting temperatures.
435
436 1.0.2   2008-07-25
437 ------------------
438
439 * Accommodate blade systems with no fans or powersupplies, i.e. accept
440   errors from omreport when trying to check fans or powersupplies on
441   blade servers.
442 * Accommodate newer hardware with slightly different omreport
443   options. Use the newer options if they exist. Not really necessary
444   yet, but deprecated options may be removed in future versions of
445   Dell OpenManage.
446
447 1.0.1   2008-07-18
448 ------------------
449
450 * When everything is OK, check_openmanage now outputs the same info as
451   Gerhard Lausser's excellent check_hpasm plugin does for HP servers:
452
453   OK - System: 'poweredge 2850', S/N: 'XXXXXXX', ROM: 'A06
454   10/03/2006', hardware working fine, 2 logical drives, 4 physical
455   drives
456
457 1.0.0   2008-07-15
458 ------------------
459
460 * Initial release