]> git.uio.no Git - check_openmanage.git/blob - CHANGES
fix
[check_openmanage.git] / CHANGES
1 3.7.0   2011-08-15
2 ------------------
3
4 * Major overhaul of the perfdata code. This includes API breakage and
5   fixes the following:
6   - Probes were not sorted correctly
7   - Voltage data was not included
8 * The PNP template check_openmanage.php has been redone to work with
9   the changes in perfdata output from the plugin
10 * A new option '--legacy-perfdata' will make the the plugin output the
11   performance data in the old format
12 * Added support for a configuration file
13 * Added manual page for the configuration file
14 * If using html output, URLs will now open in a new window
15 * Added a compatibility fix for OMSA 6.5.0, related to performance
16   data for amperage probes when the plugin is used in local
17   mode. Thanks to Benedikt Meyer for a patch.
18
19 3.6.8   2011-06-07
20 ------------------
21
22 * Added workaround for a rare condition in which blade detection fails
23   because the chassis IDs for the blade and interconnect board have
24   switched places in the BaseBoardType SNMP table.
25
26 3.6.7   2011-05-12
27 ------------------
28
29 * A regression wrt. non-certified drives were fixed. The plugin failed
30   to identify non-certified physical drives via SNMP.
31 * Added the ability to blacklist non-certified drives with the
32   'pdisk_cert' blacklisting keyword.
33
34 3.6.6   2011-04-28
35 ------------------
36
37 * Fixed typo in help output
38 * SD card check is now included if the parameter '--only chassis' is
39   specified
40 * The plugin will issue a proper warning if a physical drive is
41   uncertified, instead of an unspecified warning. One or more
42   uncertified drives will make the controller go into a non-critical
43   (warning) state.
44 * Slightly improved reporting of fan status
45 * Exit with value 3 (unknown) if printing debug, help or version
46   info. This is considered best practice for Nagios plugins.
47 * Workaround added for logical SAS connectors to external storage
48   enclosures, when using check_openmanage in local mode with OMSA
49   6.4.0 or later versions. The output from omreport could contain
50   lines that the plugin was unable to parse, which would lead to
51   internal errors.
52
53 3.6.5   2011-02-09
54 ------------------
55
56 * Fix counting of components when blacklisting is used. Components
57   should be counted even if blacklisted
58 * Added some unsupported vdisk types to the list. The OMSA MIB
59   identifies these, but lists them as unsupported.
60 * Added option '-B' or '--show-blacklist' to show any blacklistings in
61   the OK output
62 * Fixed a bug for checking voltage probes, if the reading is missing
63   via SNMP.
64 * Fixed a regression bug for a power monitoring corner case.
65
66 3.6.4   2011-01-04
67 ------------------
68
69 * Added more robustness wrt. values from OMSA obtained via SNMP, to
70   avoid internal errors where non-important values are missing.
71
72 3.6.3   2010-12-13
73 ------------------
74
75 * A few compatibility fixes for OMSA 6.4.0 were added.
76
77 3.6.2   2010-11-25
78 ------------------
79
80 * Added support for IPv6 when checking via SNMP. IPv6 can be turned on
81   with the option '-6' or '--ipv6'. The default is IPv4 if the option
82   is not present.
83 * Added support for TCP when checking vis SNMP. The option '--tcp' can
84   be used to turn on TCP. The default transport protocol is UDP if the
85   option is not present.
86 * The mode of operation (local or SNMP) is shown in the debug
87   output. If SNMP is used, the debug output will also show the SNMP
88   protocol version, IP version and transport protocol (UDP or TCP).
89 * Amperage probe status via SNMP is of type "probe status", not
90   regular status. This has been fixed.
91 * Massive overall robustness improvements to handle OMSA bugs where
92   some information from OMSA is missing.
93 * Memory module enumeration via SNMP changed somewhat to reflect
94   enumeration provided by omreport. This ensures that the plugin's
95   output is identical in SNMP or local mode wrt. dimms IDs.
96 * Fan enumeration via SNMP changed somewhat to reflect enumeration
97   provided by omreport. This ensures that the plugin's output is
98   identical in SNMP or local mode wrt. fan IDs.
99
100 3.6.1   2010-11-02
101 ------------------
102
103 * Included new check for SD cards. Newer servers such as the R710 can
104   have SD cards installed, these should be monitored. The SD card
105   check is on by default. A new blacklisting keyword 'sd' has been
106   added. The SD card check can be turned off with '--check sdcard=0'.
107 * Handle special cases where power monitoring capability is disabled
108   due to non-redundant and/or non-instrumented power supplies.
109 * For physical disks probed via SNMP, check that values for vendor,
110   product ID and capacity is available before attempting to display
111   those values.
112 * If a physical disk is in sufficiently bad condition, the vendor
113   field reported by OMSA may be empty. The plugin now handles this
114   situation without throwing an internal error.
115
116
117 3.6.0   2010-08-30
118 ------------------
119
120 * Storage is no longer allowed to be absent. If the plugin doesn't
121   find a storage controller, it will give an alert. For diskless
122   systems or servers without a Dell controller that OMSA recognizes
123   you will now have to specify '--no-storage' or '--check storage=0'
124   to work around this.
125 * Report the system revision (if applicable) wherever the model name
126   is printed. E.g. "PowerEdge 2950 III" instead of "PowerEdge 2950".
127 * Small change in search path for omreport: The new location for OMSA
128   6.2.0 and later on Linux will be attempted first.
129 * Small bugfix for the '--check' parameter, if the argument is a
130   filename. The file could not contain a linebreak, this has been
131   fixed.
132 * Added an option '--no-storage', which is equivalent to the general
133   option '--check storage=0'.
134
135
136 3.5.10  2010-07-14
137 ------------------
138
139 * If a physical disk is a hot spare, display this information in
140   the debug output
141 * Report the bus protocol (e.g. SAS, SATA) and media type (e.g. HDD,
142   SDD) for physical disks in the debug output, if applicable
143 * Minor fix for 100GB physical disks, write "100GB" instead of "99GB"
144 * SNMP: Use new features of OMSA 6.3.0 to display occupied and total
145   slots in storage enclosures, if applicable. This information is not
146   available with omreport and check_openmanage will not display this
147   info in local mode.
148 * SNMP: Added new processor IDs from the OMSA 6.3.0 MIBs
149 * SNMP: Use connection tables in a proper way to determine controller
150   and enclosure IDs, for use with physical disks and enclosure
151   components (fan, temp sensors etc.). This fixes a long standing bug
152   for servers with more than one controller, if checked via SNMP.
153 * SNMP: Use the nexus ID as last resort to find the controller for
154   physical disks. Workaround for older, broken OMSA versions.
155 * SNMP: Identify enclosures (e.g. '2:0:0') properly so that the
156   reporting with SNMP corresponds to the same report with omreport.
157 * SNMP: added a couple of workarounds for pre-historic OMSA versions
158
159
160 3.5.9   2010-06-29
161 ------------------
162
163 * More fine-grained reporting of temperature warnings for enclosure
164   temperature probes.
165 * Max/min temperature limits for enclosure temp probes are reported in
166   the debug output
167 * Report enclosure temperature probes that are "Inactive" as ok
168 * Don't try to print out the reading of enclosure temperature probes
169   if the reading doesn't exist or is not an integer
170 * Report enclosure EMMs that are "Not Installed" as ok, instead of
171   critical
172 * Corrected typo in the PNP4Nagios template
173
174
175 3.5.8   2010-06-17
176 ------------------
177
178 * Remove reporting of which controller a logical drive is "attached"
179   to, since this information can't be reliably extracted via SNMP.
180 * Avoid collecting Lun ID via SNMP for virtual disks, we don't use it
181 * Report total memory and number of dimms in the ok output
182 * Difference in reporting if amperage probes have discrete readings
183 * Workaround for broken amperage probes
184 * Added workaround for bad temperature probes that yields no reading
185   in SNMP mode
186 * Get OMSA version via SNMP slightly more efficiently
187
188
189 3.5.7   2010-03-19
190 ------------------
191
192 * Added robustness for received SNMP values that are not defined in
193   the MIB. Instead of throwing a perl warning when this happens, the
194   plugin will not report the undefined value.
195 * Defined "Replacing" as a defined state for physical disks in SNMP
196   mode, even though this state is not defined in the MIB. It is
197   reported as such by omreport.
198 * Physical disk brand/model is now reported when the state of the disk
199   is "Rebuilding" or "Replacing".
200 * The state of a physical disk is reported in parentheses when
201   predictive failure is detected. It is useful to know if a disk is
202   online, offline, spare or even failed when predictive failure is
203   reported.
204 * Handling of physical disk predictive failure has been improved
205   overall.
206 * Refactoring of the perfdata code. In conformance with the plugin
207   development guidelines, the UOM (unit of measure) previously
208   reported in the perfdata output has been removed.
209 * The -p or --perfdata option now
210   takes an optional agrument 'minimal', which triggers shorter names
211   for the perfomance data labels. This shortens the output and is a
212   workaround for systems where the amount of output exceeds the 1024
213   char limit of NRPE.
214 * The PNP4Nagios template has been updated. Users of check_openmanage
215   and PNP4Nagios are advised to upgrade. This version of
216   check_openmanage needs the new template.
217 * Lots of other small improvements and updates.
218
219
220 3.5.6   2010-02-23
221 ------------------
222
223 * New option '--use-get_table' is added as a workaround for SNMPv3 on
224   Windows using net-snmp. This option will make check_openmanage use
225   the Net::SNMP function get_table() instead of get_entries() to
226   collect information via SNMP.
227 * Include a blacklisting option 'ctrl_pdisk' which takes the
228   controller number as argument. This blacklisting option only works
229   with omreport and is a workaround for broken disk firmwares that
230   contain illegal XML characters. These characters makes openmanage
231   barf and exit with an error. Patch from Bas Couwenberg.
232 * If the blacklisting keyword "all" is supplied for a component type,
233   that component type is not checked at all, i.e. the commands are
234   never executed. This will make check_openmanage execute faster if
235   blacklisting is heavily used.
236 * Option '--htmlinfo' now has a shorter equivalent '-I'
237 * The option '--short-state' now has a shorter equivalent '-S'
238
239
240 3.5.5   2010-01-22
241 ------------------
242
243 * Fixed an SNMP bug where the plugin didn't handle OID indexes that
244   were not sequential. Thanks to Gianluca Varenni for reporting.
245 * Fixed an SNMP bug when checking old hardware such as the PE 2650 and
246   PE 750. The controller id for physical drives were collected and
247   displayed incorrectly. This release uses an additional OID to fetch
248   this info, which would otherwise be unavailable. Thanks to Gianluca
249   Varenni for reporting this bug.
250 * Should use %snmp_probestatus, not %snmp_status when checking the
251   status of voltage probes. Thanks to Ken McKinlay for a patch.
252 * Fix when identifying blades via SNMP with very old OMSA
253   versions. Patch from Ken McKinlay.
254 * Better way of finding the ID of physical drives via SNMP
255
256
257 3.5.4   2010-01-13
258 ------------------
259
260 * Added support for storport driver version for controllers, only
261   applicable on servers running Windows.  A new blacklisting keyword
262   for suppressing storport driver messages was added.
263 * The "all" keyword in blacklisting is now case insensitive.
264 * More fine-grained reporting in the rare case where a controller
265   battery fails during learning and charging states.
266 * New improved way of reporting perl warnings during execution of the
267   plugin.
268
269
270 3.5.3   2009-12-17
271 ------------------
272
273 * Fix for path to omreport on Linux with OMSA 6.2.0
274 * A couple of other small fixes
275
276
277 3.5.2   2009-11-17
278 ------------------
279
280 * Fix for undefined device name for logical drives (thanks to Pontus
281   Fuchs for a patch)
282 * Fixed a bug in the PNP4Nagios template, that prevented the template
283   from working with PNP4Nagios 0.6. Thanks to the PNP4Nagios team for
284   the fix.
285 * Other small fixes
286
287 3.5.1   2009-10-22
288 ------------------
289
290 * CPU type, family etc. are now reported in case of a CPU failure (and
291   in the debug output)
292 * The debug output now reports Openmanage version and plugin version
293
294
295 3.5.0   2009-10-13
296 ------------------
297
298 * New option '-a' or '--all' turns on checking of everything
299 * The manual page (POD info) is removed from the script and is now in
300   a separate file, to make check_openmanage fully ePN compatible
301 * ePN is no longer disabled by default, check_openmanage no longer has
302   an opinion on whether it should run under ePN or not
303 * The '-m' or '--man' option is no longer available
304 * The option '-v' or '--verbose' is renamed to '-d' or '--debug',
305   which makes more sense wrt. its usage
306 * The '-g' or '--global' option is removed. Checking the global health
307   status is now default if applicable
308 * Checking intrusion detection is now turned on by default
309 * The obsolete option '--snmp' is removed
310 * The option '--state' now has a shorter equivalent '-s'
311 * The basename stuff and options '--only-critical' and
312   '--only-warning' are now replaced by an option '--only'
313 * If plugin is run by Nagios, redirect stderr to stdout
314 * Added option '--omreport', that lets the user specify the full path
315   to the omreport binary
316 * Added non-8bit-legacy default search paths for omreport.exe for
317   Windows boxen
318 * Minor changes to the plugin output, for consistency
319 * New blacklisting keyword 'bat_charge' disables warning messages
320   related to controller cache battery charging. Thanks to Robert
321   Heinzmann for a patch.
322 * For blacklisting, the component ID kan now be "ALL", in which all
323   components of that type is blacklisted.
324 * Man page is moved to manual section 8
325
326
327 3.4.9   2009-08-07
328 ------------------
329
330 * Fixed a bug that could cause errors and weird results when checking
331   cooling devices (fans) via SNMP. Thanks to Ken McKinlay for spotting
332   this bug and reporting it.
333
334 3.4.8   2009-07-31
335 ------------------
336
337 * For failed physical drives, check_openmanage will now output the
338   drive's vendor, model and size in GB or TB.
339
340 3.4.7   2009-07-24
341 ------------------
342
343 * The -s|--snmp option was redundant and no longer does anything. SNMP
344   is triggered automatically if the -H|--hostname option is
345   present. The -s|--snmp option is kept for compatibility, but has no
346   effect.
347
348 3.4.6   2009-07-07
349 ------------------
350
351 * Added support for performance data (temperatures) from attached
352   storage enclosures such as the MD1000
353
354 3.4.5   2009-06-22
355 ------------------
356
357 * Fixed a regression in the --htmlinfo option when it is not supplied
358   with an argument
359
360 3.4.4   2009-06-22
361 ------------------
362
363 * New option --htmlinfo adds clickable HTML links in the plugin's
364   output
365
366 3.4.3   2009-06-11
367 ------------------
368
369 * Fixed a regression bug in CPU and power supply reporting that only
370   affects verbose output
371 * If blacklisting is used, the global health check (via the --global
372   option) is now negated. Checking the global health doesn't make
373   sense when one or more components is blacklisted. Thanks to Rene
374   Beaulieu for reporting this bug
375 * The PNP4Nagios template is now included in the tarball and zip
376   archive
377
378 3.4.2   2009-06-03
379 ------------------
380
381 * Improved memory error reporting, when using omreport
382 * Collect performance data from pwrmonitoring (amperage probes) that
383   were previously ignored when using omreport
384
385 3.4.1   2009-05-25
386 ------------------
387
388 * Improved memory error reporting, when using SNMP
389 * Other small ehnancements
390
391 3.4.0   2009-05-25
392 ------------------
393
394 * The plugin is now compatible with the Nagios embedded Perl
395   interpreter (ePN) in theory. However, the plugin will not not use
396   ePN by default. We don't want any "accidents".
397 * License is now GPLv3, previously only specified as "GPL"
398 * New options --only-critical and --only-warning. With these options
399   the plugin will only print critical or warning alerts, respectively.
400 * Bugfixes and speed enhancements in the storage section, when
401   checking enclosure components via omreport
402 * The --okinfo option is now less verbose and more to the point
403 * Lots of code refactoring for readability, maintainability and
404   robustness
405
406 3.3.2   2009-05-05
407 ------------------
408
409 * Fixed a bug in the storage section, when checking controllers. This
410   is an obscure bug that only manifests itself in the odd case where a
411   server has multiple controllers, and one of the controllers are
412   missing some of the OIDs, in which case these OIDs will be missing
413   for the other controllers as well. The change is minor and only
414   includes using get_table() instead of get_entries() to collect the
415   SNMP result. Thanks to Stephan Bovet for reporting this bug.
416
417 3.3.1   2009-04-28
418 ------------------
419
420 * The --perfdata option can now optionally take an argument
421   "multiline", which makes the plugin produce multiline performance
422   data output in a Nagios 3.x way. Not really needed, but the plugin
423   output is prettier.
424 * Added comment within the 10 first lines to disable the nagios
425   embedded perl (ePN) interpreter by default for Nagios 3.x
426 * Improvements in the performance data output. Units are now included
427
428 3.3.0   2009-04-07
429 ------------------
430
431 * Added --global option, which turns on checking of everything. If
432   used with SNMP, the global system health status is also probed, to
433   protect the user against bugs in the plugin. If used with omreport,
434   the overall chassis health is used.
435 * Support for SNMP version 3
436 * New check added: esmhealth. This checks the overall health of the
437   ESM log, i.e. the fill grade. More than 80% means a warning message
438 * Fixed alert log reporting to use the same format as for the ESM log
439 * Output messages are now sorted by severity
440 * Minor changes in how out-of-date controller firmware/driver is
441   reported
442 * Code refactoring and cleanup
443
444 3.2.7   2009-03-29
445 ------------------
446
447 * Use "omreport about" to collect OMSA version. Slightly faster than
448   "omreport system version". This should give a small speedup in
449   certain configurations
450 * Fixed typo in output when a logical drive is rebuilding. Thanks to
451   Andreas Olsson for reporting
452 * Improved reporting of ESM log content
453 * Added omreport.sh as alternate omreport path
454 * Lots of other small fixes and enhancements
455
456 Plus: A few changes to make the plugin work with old PowerEdge models
457 (e.g. 2550, 2450) and/or old OMSA versions (e.g. version 4.5):
458
459 * Use the chassisModelName OID to determine if SNMP works (instead of
460   BaseboardType)
461 * No longer require a response when checking baseboard type via
462   SNMP. If there is no response, we assume that we're not dealing with
463   a blade server
464
465 Thanks to Christian McHugh for help with testing and debugging this
466 stuff
467
468 3.2.6   2009-03-05
469 ------------------
470
471 * Use 'omreport system operatingsystem' to collect OS info, instead of
472   'omreport system' version which is incredibly slow. This should speed
473   things up in certain configurations.
474 * A few speedups, don't collect information that isn't needed
475 * Man page fixes
476
477 3.2.5   2009-02-24
478 ------------------
479
480 * New option --linebreak to specify the separator between line in case
481   of multiline output
482 * Added support for 64bit Windows. Thanks to Patrick Hemmen for a patch
483 * [Patrick Hemmen] Added install.bat for Windows installation
484 * [Patrick Hemmen] Improvements on install.sh. Will now install in
485   /usr/lib64 for x86_64
486 * RPMs are now architecture dependent, because of different libdir
487
488 3.2.4   2009-02-17
489 ------------------
490
491 * New option -o|--ok-info to display extra information when everything
492   is ok. The plugin can now display storage firmware and driver info,
493   DRAC and BMC firmware, and OMSA version
494 * Support for setting custom minimum temperature thresholds via the
495   -c|--critical and -w|--warning options
496 * Better and more detailed temperature error reporting
497 * Bugfix in the amperage report (including performance data). The
498   plugin now takes into account the correct unit and measurement for
499   amperage probes (other than watts)
500 * New option --port lets the user specify the remote SNMP port number
501
502 3.2.3   2009-02-09
503 ------------------
504
505 * Regression fix: Use the older Processor Device SNMP OIDs for older
506   PowerEdge models, that don't have the new Processor Device Status
507   OIDs. Thanks to Nicole Hähnel for reporting this bug.
508 * Default output (when there are no alerts) now shows RAC firmware,
509   BMC firmware, info about controllers and enclosures (firmware,
510   driver).
511
512 3.2.2   2009-02-03
513 ------------------
514
515 * Regression fix: Ignore unoccupied CPU slots with SNMP probing. This
516   fixes a bug introduced in versjon 3.2.1, which would output
517   something like this if one or more CPU slots were empty: CPU 1 needs
518   attention ()
519
520 3.2.1   2009-02-03
521 ------------------
522
523 * Use Processor Device Status Table OIDs instead of Processor Device
524   Table when checking CPUs via SNMP
525 * Bugfix: don't report throttled CPUs as warnings when checking via
526   SNMP (same as for checking locally)
527
528 3.2.0   2009-01-27
529 ------------------
530
531 * New options --state and --short-state for displaying service state
532   along with the alert
533 * Lots of small fixes for code readability and maintainability
534
535 3.1.1   2009-01-12
536 ------------------
537
538 * Support for running natively on Windows (using omreport.exe). Thanks
539   to Peter Jestico for a patch.
540 * Support for compiled Windows version, i.e. check_openmanage.exe is
541   now a legal script name.
542 * Exit with error if script basename is illegal/unknown
543 * Various small fixes
544
545 3.1.0   2008-12-26
546 ------------------
547
548 * Use of alternate basenames for checking only one class of components
549 * Added support for checking the ESM log via SNMP
550 * Code refactoring for robustness and maintainability
551 * Numerous small fixes and enhancements
552 * Added install script in distribution tarball
553
554 3.0.2   2008-12-20
555 ------------------
556
557 * The script no longer aborts if it can't get system information via
558   SNMP. Give a warning instead, as this is not a critical error
559 * Increased robustness when checking controllers
560
561 3.0.1   2008-12-11
562 ------------------
563
564 * Man page fix in the 'check' section. Thanks to Ansgar Dahlen for
565   reporting this.
566 * Allow invalid command error from 'omreport chassis pwrmonitoring'
567 * Various small fixes
568
569 3.0.0   2008-12-04
570 ------------------
571
572 * Use unique IDs for storage components with regard to blacklisting,
573   which means that the blacklisting API has changed
574 * Added checks for storage components: connectors (channels),
575   enclosures, enclosure fans, enclosure power supplies, enclosure
576   temperature probes and enclosure management modules (EMMs)
577 * Improved verbose output
578 * New option -t|--timeout for setting the plugin timeout
579 * New option -w|--warning for setting custom temperature warning
580   thresholds
581 * New option -c|--critical for setting custom temperature critical
582   thresholds
583 * Option --check can no longer be specified in its short form (-c)
584 * Code cleanup and improvements
585
586 2.1.1   2008-11-24
587 ------------------
588
589 * The workaround for the OMSA bug introduced in OMSA 5.5.0 didn't take
590   multiple controllers into account. This has been fixed.
591
592 2.1.0   2008-11-19
593 ------------------
594
595 * New option -i|--info prefixes all alerts with the service tag
596 * New option -e|--extinfo gives and extra line of output in case of an
597   alert (model and service tag)
598 * New option --postmsg lets the user specify a post message string,
599   with info such as model, service tag etc.
600 * Options -b|--blacklist and -c|--check can now be specified multiple
601   times (actually quite useful)
602
603 2.0.9   2008-11-17
604 ------------------
605
606 * Slightly improved output for alerts on logical drives (vdisks)
607 * Now shows a rebuilding physical disk as a warning, as this is
608   usually accompanied by a degraded vdisk. Previous versions didn't
609   show this at all (omreport classifies it as "OK").
610
611 2.0.8   2008-11-14
612 ------------------
613
614 * Slightly improved output for charging controller batteries
615
616 2.0.7   2008-11-12
617 ------------------
618
619 * Bugfix for reporting physical drives with predictive failure (both
620   via NRPE and SNMP)
621
622 2.0.6   2008-10-30
623 ------------------
624
625 * Fix bug in option handling (ambiguous options)
626 * Slightly improved output if checking the storage subsystem is turned
627   off
628 * Don't complain if there are no logical drives. This is OK. Thanks to
629   Jamie Henderson for reporting this
630
631 2.0.5   2008-10-29
632 ------------------
633
634 * Fix bug in SNMP status level table
635
636 2.0.4   2008-10-29
637 ------------------
638
639 * Added workaround for a BUG introduced in OpenManage 5.5.0. OM
640   sometimes adds a newline in the controller driver version name,
641   which leads to problems parsing the output. Thanks to Hiren Patel
642   for bringing this to my attention.
643
644 2.0.3   2008-10-28
645 ------------------
646
647 * (snmp) Improved handling of cases where OM is not working properly
648
649 2.0.2   2008-10-27
650 ------------------
651
652 * Fixed issue where controller number for physical disks can't be
653   established via SNMP (now identifies as controller no. -1)
654
655 2.0.1   2008-10-23
656 ------------------
657
658 * Correctly identifies and reports error condition in which OpenManage
659   has stopped working (it happens)
660
661 2.0.0   2008-10-23
662 ------------------
663
664 * SNMP support
665 * Same options for checking, blacklisting etc. supported with SNMP
666 * Same output with SNMP as with NRPE
667
668 1.2.1   2008-09-25
669 ------------------
670
671 * Collects performance data if the option '-p' or '--perfdata' is
672   supplied.
673 * New blacklisting directives ctrl_fw and ctrl_driver
674   added. Suppresses the "special" warning messages concerning outdated
675   controller firmware and driver. Useful if you can't or won't
676   upgrade.
677
678 1.1.2   2008-08-06
679 ------------------
680
681 * Fix getting system model and serial number for newer blades
682
683 1.1.1   2008-08-06
684 ------------------
685
686 * Three new checks added:
687   - System battery probes (typical CMOS battery). Newer poweredge
688     models have these
689   - Power consumption monitoring (if the server supports it)
690   - ESM log, with same functionality as the alert log check. Disabled
691     by default.
692
693 1.1.0   2008-08-04
694 ------------------
695
696 * Internal refactoring: use ssv-formatted output from openmanage,
697   resulting in slightly faster execution and increased robustness.
698 * If /usr/bin/omreport doesn't exist, try
699   /opt/dell/srvadmin/oma/bin/omreport.
700 * Allow for no instrumented/redundant power supplies. Needed on
701   low-end poweredge models and blades.
702
703 1.0.3   2008-07-25
704 ------------------
705
706 * Openmanage reports non-critical warning about throttled CPUs on new
707   hardware models. Most og us use ondemand CPU frequency scaling (with
708   throttled CPUs as a result). This specific non-critical warning (CPU
709   Throttled) is ignored from now on.
710 * Remove superfluous Celcius sign when reporting temperatures.
711
712 1.0.2   2008-07-25
713 ------------------
714
715 * Accommodate blade systems with no fans or powersupplies, i.e. accept
716   errors from omreport when trying to check fans or powersupplies on
717   blade servers.
718 * Accommodate newer hardware with slightly different omreport
719   options. Use the newer options if they exist. Not really necessary
720   yet, but deprecated options may be removed in future versions of
721   Dell OpenManage.
722
723 1.0.1   2008-07-18
724 ------------------
725
726 * When everything is OK, check_openmanage now outputs the same info as
727   Gerhard Lausser's excellent check_hpasm plugin does for HP servers:
728
729   OK - System: 'poweredge 2850', S/N: 'XXXXXXX', ROM: 'A06
730   10/03/2006', hardware working fine, 2 logical drives, 4 physical
731   drives
732
733 1.0.0   2008-07-15
734 ------------------
735