1 3.6.5   2011-02-09
2 ------------------
3
4 * Fix counting of components when blacklisting is used. Components
5   should be counted even if blacklisted
6 * Added some unsupported vdisk types to the list. The OMSA MIB
7   identifies these, but lists them as unsupported.
8 * Added option '-B' or '--show-blacklist' to show any blacklistings in
9   the OK output
10 * Fixed a bug for checking voltage probes, if the reading is missing
11   via SNMP.
12 * Fixed a regression bug for a power monitoring corner case.
13
14 3.6.4   2011-01-04
15 ------------------
16
17 * Added more robustness wrt. values from OMSA obtained via SNMP, to
18   avoid internal errors where non-important values are missing.
19
20 3.6.3   2010-12-13
21 ------------------
22
23 * A few compatibility fixes for OMSA 6.4.0 were added.
24
25 3.6.2   2010-11-25
26 ------------------
27
28 * Added support for IPv6 when checking via SNMP. IPv6 can be turned on
29   with the option '-6' or '--ipv6'. The default is IPv4 if the option
30   is not present.
31 * Added support for TCP when checking vis SNMP. The option '--tcp' can
32   be used to turn on TCP. The default transport protocol is UDP if the
33   option is not present.
34 * The mode of operation (local or SNMP) is shown in the debug
35   output. If SNMP is used, the debug output will also show the SNMP
36   protocol version, IP version and transport protocol (UDP or TCP).
37 * Amperage probe status via SNMP is of type "probe status", not
38   regular status. This has been fixed.
39 * Massive overall robustness improvements to handle OMSA bugs where
40   some information from OMSA is missing.
41 * Memory module enumeration via SNMP changed somewhat to reflect
42   enumeration provided by omreport. This ensures that the plugin's
43   output is identical in SNMP or local mode wrt. dimms IDs.
44 * Fan enumeration via SNMP changed somewhat to reflect enumeration
45   provided by omreport. This ensures that the plugin's output is
46   identical in SNMP or local mode wrt. fan IDs.
47
48 3.6.1   2010-11-02
49 ------------------
50
51 * Included new check for SD cards. Newer servers such as the R710 can
52   have SD cards installed, these should be monitored. The SD card
53   check is on by default. A new blacklisting keyword 'sd' has been
54   added. The SD card check can be turned off with '--check sdcard=0'.
55 * Handle special cases where power monitoring capability is disabled
56   due to non-redundant and/or non-instrumented power supplies.
57 * For physical disks probed via SNMP, check that values for vendor,
58   product ID and capacity is available before attempting to display
59   those values.
60 * If a physical disk is in sufficiently bad condition, the vendor
61   field reported by OMSA may be empty. The plugin now handles this
62   situation without throwing an internal error.
63
64
65 3.6.0   2010-08-30
66 ------------------
67
68 * Storage is no longer allowed to be absent. If the plugin doesn't
69   find a storage controller, it will give an alert. For diskless
70   systems or servers without a Dell controller that OMSA recognizes
71   you will now have to specify '--no-storage' or '--check storage=0'
72   to work around this.
73 * Report the system revision (if applicable) wherever the model name
74   is printed. E.g. "PowerEdge 2950 III" instead of "PowerEdge 2950".
75 * Small change in search path for omreport: The new location for OMSA
76   6.2.0 and later on Linux will be attempted first.
77 * Small bugfix for the '--check' parameter, if the argument is a
78   filename. The file could not contain a linebreak, this has been
79   fixed.
80 * Added an option '--no-storage', which is equivalent to the general
81   option '--check storage=0'.
82
83
84 3.5.10  2010-07-14
85 ------------------
86
87 * If a physical disk is a hot spare, display this information in
88   the debug output
89 * Report the bus protocol (e.g. SAS, SATA) and media type (e.g. HDD,
90   SDD) for physical disks in the debug output, if applicable
91 * Minor fix for 100GB physical disks, write "100GB" instead of "99GB"
92 * SNMP: Use new features of OMSA 6.3.0 to display occupied and total
93   slots in storage enclosures, if applicable. This information is not
94   available with omreport and check_openmanage will not display this
95   info in local mode.
96 * SNMP: Added new processor IDs from the OMSA 6.3.0 MIBs
97 * SNMP: Use connection tables in a proper way to determine controller
98   and enclosure IDs, for use with physical disks and enclosure
99   components (fan, temp sensors etc.). This fixes a long standing bug
100   for servers with more than one controller, if checked via SNMP.
101 * SNMP: Use the nexus ID as last resort to find the controller for
102   physical disks. Workaround for older, broken OMSA versions.
103 * SNMP: Identify enclosures (e.g. '2:0:0') properly so that the
104   reporting with SNMP corresponds to the same report with omreport.
105 * SNMP: added a couple of workarounds for pre-historic OMSA versions
106
107
108 3.5.9   2010-06-29
109 ------------------
110
111 * More fine-grained reporting of temperature warnings for enclosure
112   temperature probes.
113 * Max/min temperature limits for enclosure temp probes are reported in
114   the debug output
115 * Report enclosure temperature probes that are "Inactive" as ok
116 * Don't try to print out the reading of enclosure temperature probes
117   if the reading doesn't exist or is not an integer
118 * Report enclosure EMMs that are "Not Installed" as ok, instead of
119   critical
120 * Corrected typo in the PNP4Nagios template
121
122
123 3.5.8   2010-06-17
124 ------------------
125
126 * Remove reporting of which controller a logical drive is "attached"
127   to, since this information can't be reliably extracted via SNMP.
128 * Avoid collecting Lun ID via SNMP for virtual disks, we don't use it
129 * Report total memory and number of dimms in the ok output
130 * Difference in reporting if amperage probes have discrete readings
131 * Workaround for broken amperage probes
132 * Added workaround for bad temperature probes that yields no reading
133   in SNMP mode
134 * Get OMSA version via SNMP slightly more efficiently
135
136
137 3.5.7   2010-03-19
138 ------------------
139
140 * Added robustness for received SNMP values that are not defined in
141   the MIB. Instead of throwing a perl warning when this happens, the
142   plugin will not report the undefined value.
143 * Defined "Replacing" as a defined state for physical disks in SNMP
144   mode, even though this state is not defined in the MIB. It is
145   reported as such by omreport.
146 * Physical disk brand/model is now reported when the state of the disk
147   is "Rebuilding" or "Replacing".
148 * The state of a physical disk is reported in parentheses when
149   predictive failure is detected. It is useful to know if a disk is
150   online, offline, spare or even failed when predictive failure is
151   reported.
152 * Handling of physical disk predictive failure has been improved
153   overall.
154 * Refactoring of the perfdata code. In conformance with the plugin
155   development guidelines, the UOM (unit of measure) previously
156   reported in the perfdata output has been removed.
157 * The -p or --perfdata option now
158   takes an optional agrument 'minimal', which triggers shorter names
159   for the perfomance data labels. This shortens the output and is a
160   workaround for systems where the amount of output exceeds the 1024
161   char limit of NRPE.
162 * The PNP4Nagios template has been updated. Users of check_openmanage
163   and PNP4Nagios are advised to upgrade. This version of
164   check_openmanage needs the new template.
165 * Lots of other small improvements and updates.
166
167
168 3.5.6   2010-02-23
169 ------------------
170
171 * New option '--use-get_table' is added as a workaround for SNMPv3 on
172   Windows using net-snmp. This option will make check_openmanage use
173   the Net::SNMP function get_table() instead of get_entries() to
174   collect information via SNMP.
175 * Include a blacklisting option 'ctrl_pdisk' which takes the
176   controller number as argument. This blacklisting option only works
177   with omreport and is a workaround for broken disk firmwares that
178   contain illegal XML characters. These characters makes openmanage
179   barf and exit with an error. Patch from Bas Couwenberg.
180 * If the blacklisting keyword "all" is supplied for a component type,
181   that component type is not checked at all, i.e. the commands are
182   never executed. This will make check_openmanage execute faster if
183   blacklisting is heavily used.
184 * Option '--htmlinfo' now has a shorter equivalent '-I'
185 * The option '--short-state' now has a shorter equivalent '-S'
186
187
188 3.5.5   2010-01-22
189 ------------------
190
191 * Fixed an SNMP bug where the plugin didn't handle OID indexes that
192   were not sequential. Thanks to Gianluca Varenni for reporting.
193 * Fixed an SNMP bug when checking old hardware such as the PE 2650 and
194   PE 750. The controller id for physical drives were collected and
195   displayed incorrectly. This release uses an additional OID to fetch
196   this info, which would otherwise be unavailable. Thanks to Gianluca
197   Varenni for reporting this bug.
198 * Should use %snmp_probestatus, not %snmp_status when checking the
199   status of voltage probes. Thanks to Ken McKinlay for a patch.
200 * Fix when identifying blades via SNMP with very old OMSA
201   versions. Patch from Ken McKinlay.
202 * Better way of finding the ID of physical drives via SNMP
203
204
205 3.5.4   2010-01-13
206 ------------------
207
208 * Added support for storport driver version for controllers, only
209   applicable on servers running Windows.  A new blacklisting keyword
210   for suppressing storport driver messages was added.
211 * The "all" keyword in blacklisting is now case insensitive.
212 * More fine-grained reporting in the rare case where a controller
213   battery fails during learning and charging states.
214 * New improved way of reporting perl warnings during execution of the
215   plugin.
216
217
218 3.5.3   2009-12-17
219 ------------------
220
221 * Fix for path to omreport on Linux with OMSA 6.2.0
222 * A couple of other small fixes
223
224
225 3.5.2   2009-11-17
226 ------------------
227
228 * Fix for undefined device name for logical drives (thanks to Pontus
229   Fuchs for a patch)
230 * Fixed a bug in the PNP4Nagios template, that prevented the template
231   from working with PNP4Nagios 0.6. Thanks to the PNP4Nagios team for
232   the fix.
233 * Other small fixes
234
235 3.5.1   2009-10-22
236 ------------------
237
238 * CPU type, family etc. are now reported in case of a CPU failure (and
239   in the debug output)
240 * The debug output now reports Openmanage version and plugin version
241
242
243 3.5.0   2009-10-13
244 ------------------
245
246 * New option '-a' or '--all' turns on checking of everything
247 * The manual page (POD info) is removed from the script and is now in
248   a separate file, to make check_openmanage fully ePN compatible
249 * ePN is no longer disabled by default, check_openmanage no longer has
250   an opinion on whether it should run under ePN or not
251 * The '-m' or '--man' option is no longer available
252 * The option '-v' or '--verbose' is renamed to '-d' or '--debug',
253   which makes more sense wrt. its usage
254 * The '-g' or '--global' option is removed. Checking the global health
255   status is now default if applicable
256 * Checking intrusion detection is now turned on by default
257 * The obsolete option '--snmp' is removed
258 * The option '--state' now has a shorter equivalent '-s'
259 * The basename stuff and options '--only-critical' and
260   '--only-warning' are now replaced by an option '--only'
261 * If plugin is run by Nagios, redirect stderr to stdout
262 * Added option '--omreport', that lets the user specify the full path
263   to the omreport binary
264 * Added non-8bit-legacy default search paths for omreport.exe for
265   Windows boxen
266 * Minor changes to the plugin output, for consistency
267 * New blacklisting keyword 'bat_charge' disables warning messages
268   related to controller cache battery charging. Thanks to Robert
269   Heinzmann for a patch.
270 * For blacklisting, the component ID kan now be "ALL", in which all
271   components of that type is blacklisted.
272 * Man page is moved to manual section 8
273
274
275 3.4.9   2009-08-07
276 ------------------
277
278 * Fixed a bug that could cause errors and weird results when checking
279   cooling devices (fans) via SNMP. Thanks to Ken McKinlay for spotting
280   this bug and reporting it.
281
282 3.4.8   2009-07-31
283 ------------------
284
285 * For failed physical drives, check_openmanage will now output the
286   drive's vendor, model and size in GB or TB.
287
288 3.4.7   2009-07-24
289 ------------------
290
291 * The -s|--snmp option was redundant and no longer does anything. SNMP
292   is triggered automatically if the -H|--hostname option is
293   present. The -s|--snmp option is kept for compatibility, but has no
294   effect.
295
296 3.4.6   2009-07-07
297 ------------------
298
299 * Added support for performance data (temperatures) from attached
300   storage enclosures such as the MD1000
301
302 3.4.5   2009-06-22
303 ------------------
304
305 * Fixed a regression in the --htmlinfo option when it is not supplied
306   with an argument
307
308 3.4.4   2009-06-22
309 ------------------
310
311 * New option --htmlinfo adds clickable HTML links in the plugin's
312   output
313
314 3.4.3   2009-06-11
315 ------------------
316
317 * Fixed a regression bug in CPU and power supply reporting that only
318   affects verbose output
319 * If blacklisting is used, the global health check (via the --global
320   option) is now negated. Checking the global health doesn't make
321   sense when one or more components is blacklisted. Thanks to Rene
322   Beaulieu for reporting this bug
323 * The PNP4Nagios template is now included in the tarball and zip
324   archive
325
326 3.4.2   2009-06-03
327 ------------------
328
329 * Improved memory error reporting, when using omreport
330 * Collect performance data from pwrmonitoring (amperage probes) that
331   were previously ignored when using omreport
332
333 3.4.1   2009-05-25
334 ------------------
335
336 * Improved memory error reporting, when using SNMP
337 * Other small ehnancements
338
339 3.4.0   2009-05-25
340 ------------------
341
342 * The plugin is now compatible with the Nagios embedded Perl
343   interpreter (ePN) in theory. However, the plugin will not not use
344   ePN by default. We don't want any "accidents".
345 * License is now GPLv3, previously only specified as "GPL"
346 * New options --only-critical and --only-warning. With these options
347   the plugin will only print critical or warning alerts, respectively.
348 * Bugfixes and speed enhancements in the storage section, when
349   checking enclosure components via omreport
350 * The --okinfo option is now less verbose and more to the point
351 * Lots of code refactoring for readability, maintainability and
352   robustness
353
354 3.3.2   2009-05-05
355 ------------------
356
357 * Fixed a bug in the storage section, when checking controllers. This
358   is an obscure bug that only manifests itself in the odd case where a
359   server has multiple controllers, and one of the controllers are
360   missing some of the OIDs, in which case these OIDs will be missing
361   for the other controllers as well. The change is minor and only
362   includes using get_table() instead of get_entries() to collect the
363   SNMP result. Thanks to Stephan Bovet for reporting this bug.
364
365 3.3.1   2009-04-28
366 ------------------
367
368 * The --perfdata option can now optionally take an argument
369   "multiline", which makes the plugin produce multiline performance
370   data output in a Nagios 3.x way. Not really needed, but the plugin
371   output is prettier.
372 * Added comment within the 10 first lines to disable the nagios
373   embedded perl (ePN) interpreter by default for Nagios 3.x
374 * Improvements in the performance data output. Units are now included
375
376 3.3.0   2009-04-07
377 ------------------
378
379 * Added --global option, which turns on checking of everything. If
380   used with SNMP, the global system health status is also probed, to
381   protect the user against bugs in the plugin. If used with omreport,
382   the overall chassis health is used.
383 * Support for SNMP version 3
384 * New check added: esmhealth. This checks the overall health of the
385   ESM log, i.e. the fill grade. More than 80% means a warning message
386 * Fixed alert log reporting to use the same format as for the ESM log
387 * Output messages are now sorted by severity
388 * Minor changes in how out-of-date controller firmware/driver is
389   reported
390 * Code refactoring and cleanup
391
392 3.2.7   2009-03-29
393 ------------------
394
395 * Use "omreport about" to collect OMSA version. Slightly faster than
396   "omreport system version". This should give a small speedup in
397   certain configurations
398 * Fixed typo in output when a logical drive is rebuilding. Thanks to
399   Andreas Olsson for reporting
400 * Improved reporting of ESM log content
401 * Added omreport.sh as alternate omreport path
402 * Lots of other small fixes and enhancements
403
404 Plus: A few changes to make the plugin work with old PowerEdge models
405 (e.g. 2550, 2450) and/or old OMSA versions (e.g. version 4.5):
406
407 * Use the chassisModelName OID to determine if SNMP works (instead of
408   BaseboardType)
409 * No longer require a response when checking baseboard type via
410   SNMP. If there is no response, we assume that we're not dealing with
411   a blade server
412
413 Thanks to Christian McHugh for help with testing and debugging this
414 stuff
415
416 3.2.6   2009-03-05
417 ------------------
418
419 * Use 'omreport system operatingsystem' to collect OS info, instead of
420   'omreport system' version which is incredibly slow. This should speed
421   things up in certain configurations.
422 * A few speedups, don't collect information that isn't needed
423 * Man page fixes
424
425 3.2.5   2009-02-24
426 ------------------
427
428 * New option --linebreak to specify the separator between line in case
429   of multiline output
430 * Added support for 64bit Windows. Thanks to Patrick Hemmen for a patch
431 * [Patrick Hemmen] Added install.bat for Windows installation
432 * [Patrick Hemmen] Improvements on install.sh. Will now install in
433   /usr/lib64 for x86_64
434 * RPMs are now architecture dependent, because of different libdir
435
436 3.2.4   2009-02-17
437 ------------------
438
439 * New option -o|--ok-info to display extra information when everything
440   is ok. The plugin can now display storage firmware and driver info,
441   DRAC and BMC firmware, and OMSA version
442 * Support for setting custom minimum temperature thresholds via the
443   -c|--critical and -w|--warning options
444 * Better and more detailed temperature error reporting
445 * Bugfix in the amperage report (including performance data). The
446   plugin now takes into account the correct unit and measurement for
447   amperage probes (other than watts)
448 * New option --port lets the user specify the remote SNMP port number
449
450 3.2.3   2009-02-09
451 ------------------
452
453 * Regression fix: Use the older Processor Device SNMP OIDs for older
454   PowerEdge models, that don't have the new Processor Device Status
455   OIDs. Thanks to Nicole Hähnel for reporting this bug.
456 * Default output (when there are no alerts) now shows RAC firmware,
457   BMC firmware, info about controllers and enclosures (firmware,
458   driver).
459
460 3.2.2   2009-02-03
461 ------------------
462
463 * Regression fix: Ignore unoccupied CPU slots with SNMP probing. This
464   fixes a bug introduced in versjon 3.2.1, which would output
465   something like this if one or more CPU slots were empty: CPU 1 needs
466   attention ()
467
468 3.2.1   2009-02-03
469 ------------------
470
471 * Use Processor Device Status Table OIDs instead of Processor Device
472   Table when checking CPUs via SNMP
473 * Bugfix: don't report throttled CPUs as warnings when checking via
474   SNMP (same as for checking locally)
475
476 3.2.0   2009-01-27
477 ------------------
478
479 * New options --state and --short-state for displaying service state
480   along with the alert
481 * Lots of small fixes for code readability and maintainability
482
483 3.1.1   2009-01-12
484 ------------------
485
486 * Support for running natively on Windows (using omreport.exe). Thanks
487   to Peter Jestico for a patch.
488 * Support for compiled Windows version, i.e. check_openmanage.exe is
489   now a legal script name.
490 * Exit with error if script basename is illegal/unknown
491 * Various small fixes
492
493 3.1.0   2008-12-26
494 ------------------
495
496 * Use of alternate basenames for checking only one class of components
497 * Added support for checking the ESM log via SNMP
498 * Code refactoring for robustness and maintainability
499 * Numerous small fixes and enhancements
500 * Added install script in distribution tarball
501
502 3.0.2   2008-12-20
503 ------------------
504
505 * The script no longer aborts if it can't get system information via
506   SNMP. Give a warning instead, as this is not a critical error
507 * Increased robustness when checking controllers
508
509 3.0.1   2008-12-11
510 ------------------
511
512 * Man page fix in the 'check' section. Thanks to Ansgar Dahlen for
513   reporting this.
514 * Allow invalid command error from 'omreport chassis pwrmonitoring'
515 * Various small fixes
516
517 3.0.0   2008-12-04
518 ------------------
519
520 * Use unique IDs for storage components with regard to blacklisting,
521   which means that the blacklisting API has changed
522 * Added checks for storage components: connectors (channels),
523   enclosures, enclosure fans, enclosure power supplies, enclosure
524   temperature probes and enclosure management modules (EMMs)
525 * Improved verbose output
526 * New option -t|--timeout for setting the plugin timeout
527 * New option -w|--warning for setting custom temperature warning
528   thresholds
529 * New option -c|--critical for setting custom temperature critical
530   thresholds
531 * Option --check can no longer be specified in its short form (-c)
532 * Code cleanup and improvements
533
534 2.1.1   2008-11-24
535 ------------------
536
537 * The workaround for the OMSA bug introduced in OMSA 5.5.0 didn't take
538   multiple controllers into account. This has been fixed.
539
540 2.1.0   2008-11-19
541 ------------------
542
543 * New option -i|--info prefixes all alerts with the service tag
544 * New option -e|--extinfo gives and extra line of output in case of an
545   alert (model and service tag)
546 * New option --postmsg lets the user specify a post message string,
547   with info such as model, service tag etc.
548 * Options -b|--blacklist and -c|--check can now be specified multiple
549   times (actually quite useful)
550
551 2.0.9   2008-11-17
552 ------------------
553
554 * Slightly improved output for alerts on logical drives (vdisks)
555 * Now shows a rebuilding physical disk as a warning, as this is
556   usually accompanied by a degraded vdisk. Previous versions didn't
557   show this at all (omreport classifies it as "OK").
558
559 2.0.8   2008-11-14
560 ------------------
561
562 * Slightly improved output for charging controller batteries
563
564 2.0.7   2008-11-12
565 ------------------
566
567 * Bugfix for reporting physical drives with predictive failure (both
568   via NRPE and SNMP)
569
570 2.0.6   2008-10-30
571 ------------------
572
573 * Fix bug in option handling (ambiguous options)
574 * Slightly improved output if checking the storage subsystem is turned
575   off
576 * Don't complain if there are no logical drives. This is OK. Thanks to
577   Jamie Henderson for reporting this
578
579 2.0.5   2008-10-29
580 ------------------
581
582 * Fix bug in SNMP status level table
583
584 2.0.4   2008-10-29
585 ------------------
586
587 * Added workaround for a BUG introduced in OpenManage 5.5.0. OM
588   sometimes adds a newline in the controller driver version name,
589   which leads to problems parsing the output. Thanks to Hiren Patel
590   for bringing this to my attention.
591
592 2.0.3   2008-10-28
593 ------------------
594
595 * (snmp) Improved handling of cases where OM is not working properly
596
597 2.0.2   2008-10-27
598 ------------------
599
600 * Fixed issue where controller number for physical disks can't be
601   established via SNMP (now identifies as controller no. -1)
602
603 2.0.1   2008-10-23
604 ------------------
605
606 * Correctly identifies and reports error condition in which OpenManage
607   has stopped working (it happens)
608
609 2.0.0   2008-10-23
610 ------------------
611
612 * SNMP support
613 * Same options for checking, blacklisting etc. supported with SNMP
614 * Same output with SNMP as with NRPE
615
616 1.2.1   2008-09-25
617 ------------------
618
619 * Collects performance data if the option '-p' or '--perfdata' is
620   supplied.
621 * New blacklisting directives ctrl_fw and ctrl_driver
622   added. Suppresses the "special" warning messages concerning outdated
623   controller firmware and driver. Useful if you can't or won't
624   upgrade.
625
626 1.1.2   2008-08-06
627 ------------------
628
629 * Fix getting system model and serial number for newer blades
630
631 1.1.1   2008-08-06
632 ------------------
633
634 * Three new checks added:
635   - System battery probes (typical CMOS battery). Newer poweredge
636     models have these
637   - Power consumption monitoring (if the server supports it)
638   - ESM log, with same functionality as the alert log check. Disabled
639     by default.
640
641 1.1.0   2008-08-04
642 ------------------
643
644 * Internal refactoring: use ssv-formatted output from openmanage,
645   resulting in slightly faster execution and increased robustness.
646 * If /usr/bin/omreport doesn't exist, try
647   /opt/dell/srvadmin/oma/bin/omreport.
648 * Allow for no instrumented/redundant power supplies. Needed on
649   low-end poweredge models and blades.
650
651 1.0.3   2008-07-25
652 ------------------
653
654 * Openmanage reports non-critical warning about throttled CPUs on new
655   hardware models. Most og us use ondemand CPU frequency scaling (with
656   throttled CPUs as a result). This specific non-critical warning (CPU
657   Throttled) is ignored from now on.
658 * Remove superfluous Celcius sign when reporting temperatures.
659
660 1.0.2   2008-07-25
661 ------------------
662
663 * Accommodate blade systems with no fans or powersupplies, i.e. accept
664   errors from omreport when trying to check fans or powersupplies on
665   blade servers.
666 * Accommodate newer hardware with slightly different omreport
667   options. Use the newer options if they exist. Not really necessary
668   yet, but deprecated options may be removed in future versions of
669   Dell OpenManage.
670
671 1.0.1   2008-07-18
672 ------------------
673
674 * When everything is OK, check_openmanage now outputs the same info as
675   Gerhard Lausser's excellent check_hpasm plugin does for HP servers:
676
677   OK - System: 'poweredge 2850', S/N: 'XXXXXXX', ROM: 'A06
678   10/03/2006', hardware working fine, 2 logical drives, 4 physical
679   drives
680
681 1.0.0   2008-07-15