+3.7.0 2011-08-15
+------------------
+
+* Major overhaul of the perfdata code. This includes API breakage and
+ fixes the following:
+ - Probes were not sorted correctly
+ - Voltage data was not included
+* The PNP template check_openmanage.php has been redone to work with
+ the changes in perfdata output from the plugin
+* A new option '--legacy-perfdata' will make the the plugin output the
+ performance data in the old format
+* The old PNP template for performance data is available in the
+ distribution as 'check_openmanage_legacy.php'
+* Added support for a configuration file
+* Added manual page for the configuration file
+* If using html output, URLs will now open in a new window
+* Added a compatibility fix for OMSA 6.5.0, related to performance
+ data for amperage probes when the plugin is used in local
+ mode. Thanks to Benedikt Meyer for a patch.
+
+3.6.8 2011-06-07
+------------------
+
+* Added workaround for a rare condition in which blade detection fails
+ because the chassis IDs for the blade and interconnect board have
+ switched places in the BaseBoardType SNMP table.
+
+3.6.7 2011-05-12
+------------------
+
+* A regression wrt. non-certified drives were fixed. The plugin failed
+ to identify non-certified physical drives via SNMP.
+* Added the ability to blacklist non-certified drives with the
+ 'pdisk_cert' blacklisting keyword.
+
+3.6.6 2011-04-28
+------------------
+
+* Fixed typo in help output
+* SD card check is now included if the parameter '--only chassis' is
+ specified
+* The plugin will issue a proper warning if a physical drive is
+ uncertified, instead of an unspecified warning. One or more
+ uncertified drives will make the controller go into a non-critical
+ (warning) state.
+* Slightly improved reporting of fan status
+* Exit with value 3 (unknown) if printing debug, help or version
+ info. This is considered best practice for Nagios plugins.
+* Workaround added for logical SAS connectors to external storage
+ enclosures, when using check_openmanage in local mode with OMSA
+ 6.4.0 or later versions. The output from omreport could contain
+ lines that the plugin was unable to parse, which would lead to
+ internal errors.
+
+3.6.5 2011-02-09
+------------------
+
+* Fix counting of components when blacklisting is used. Components
+ should be counted even if blacklisted
+* Added some unsupported vdisk types to the list. The OMSA MIB
+ identifies these, but lists them as unsupported.
+* Added option '-B' or '--show-blacklist' to show any blacklistings in
+ the OK output
+* Fixed a bug for checking voltage probes, if the reading is missing
+ via SNMP.
+* Fixed a regression bug for a power monitoring corner case.
+