zampolli [Sun, 30 Oct 2011 17:14:31 +0000 (17:14 +0000)]
Method: TObjString::GetString() replaced with TObjString::String() in GetFile method (due to some changes in ROOT, the previous does not work anymore -
thanks to Matthias for the advice!)
richterm [Fri, 28 Oct 2011 22:57:48 +0000 (22:57 +0000)]
- adjusting binning of pad histograms to make single pad cluster contribution and 0.5 offset visible
- added pad histogram for hwcf data
- implementing cluster mapping without cluster id data blocks to produce the delta plots
- some corrections of histogram labels
martinez [Fri, 28 Oct 2011 18:39:04 +0000 (18:39 +0000)]
Added the possibility to select tracks on pDCA, chi2, pT and MC label. Added the possibility to study the efficiency versus pT, y and muon charge (Philippe P.)
martinez [Fri, 28 Oct 2011 16:06:41 +0000 (16:06 +0000)]
Behavior change : for mcMode=1 we keep all the kinematics, whether or not there's something in the spectrometer. Bug fix : insure the Ncontributor field of the copied vertices are correctly transported to the filtered aod (Laurent)
rpreghen [Fri, 28 Oct 2011 10:49:44 +0000 (10:49 +0000)]
this is a relatively large commit to use BPTX clock-phase measurements in
TOF
calibration.
**********************************
AliTOFRunParams calibration object
**********************************
added a new bool data member. if set, the parameters stored in the
object have
been obtained using the BPTX, therefore calibration must use BPTX.
if not set, parameters have been obtained without BPTX and calibration
must go
without BPTX.
*****************************
AliTOFcalib calibration class
*****************************
added reading of BPTX LHCClockPhase OCDB entry.
BPTX measurement is used to calibrate TOF data only if AliTOFRunParams
object
has the flag set (i.e. the params were obtained using BPTX as well) or
if BPTX
use is forced by user (default is not use).
backward compatibility of calibration will be ensured.
****************************
AliTOFPreprocessor (SHUTTLE)
****************************
ProcessT0Fill function modified. Online T0-fill will be computed and
OCDB
updated only if not using BPTX measurement in TOF calibration.
Therefore, as a
new default AliTOFRunParams entry will be put in the OCDB with use BPTX
flag
set, we don't expect to compute and update OCDB with online T0-fill
anymore
after that.
****************************
AliTOFAnalysisTaskCalibPass0
****************************
TOF C-Pass0 calibration code updated to use the BPTX as well and produce
objects with correct flags. C-Pass0 will now compute the residual shift
wrt. BPTX measurement.
morsch [Fri, 28 Oct 2011 07:03:57 +0000 (07:03 +0000)]
Modified classes AliGenMUONlib,
AliGenMUONCocktailpp and AliGenCorrHF which allow to simulate
centrality dependent production of quarkonia & HF-hadrons in Pb-Pb
and p-Pb collisions.
jklein [Thu, 27 Oct 2011 08:35:22 +0000 (08:35 +0000)]
- support raw data version 0xd (MEB)
- evaluate CRC falgs from GTU
- improve for readout order checking
- tracklet sorting available in rawstream
- labelling of raw GTU tracks in ESDs
cblume [Wed, 26 Oct 2011 19:25:29 +0000 (19:25 +0000)]
AliTRDdigitizer.cxx -> For the new name of the Nodata status in AliTRDCalChamberStatus
AliTRDcalibDB.cxx .h -> For the function related to the new status in AliTRDCalChamberStatus + the exb object with a protection against 100. I plan namely to put a default object with 100, which will indicate that the look up table as to be used. In AliTRDcalibDB, it takes the loop up take when the mean value is above 70...
AliTRDCalibChamberStatus.cxx .h -> calibration with tracks for chamber status of half chamber also
Cal/AliTRDCalChamberStatus.h .cxx -> change of definition of status, keeping the back compatibility.
AliTRDCalibTask.cxx .h -> Run the chamber status calibration + propagate the version and subersion number of the exb object used in the reconstruction
AliTRDCalibraFillHisto.cxx .h -> due to the new name of the status