Commit | Line | Data |
---|---|---|
3e42bf30 | 1 | // $Id$ |
2 | ||
3 | /*! | |
4 | ||
5 | \page README_mtrda Trigger DA | |
6 | ||
7 | The detector algorithm is implemented for the Muon Trigger in the AliRoot framework. | |
8 | The main code is located in MUONTRGda.cxx and it runs in the MUON Trigger LDC. | |
9 | ||
10 | \section da_s1 The Muon Trigger Calibration | |
11 | ||
12 | The main goal of the DA is the transfert of the modified configuration files to the FES. | |
13 | The configuration files stored in the online DB are the following: | |
14 | ||
113ad708 | 15 | - MtgGlobalCrate-<version>.dat: contains the global crate information |
16 | - MtgRegionalCrate-<version>.dat: contains the regional crate information | |
17 | - MtgLocalMask-<version>.dat: contains the local mask | |
18 | - MtgLocalLut-<version>.dat: contains the local LUT | |
19 | - MtgCurrent.dat: contains the name list of the above files with their version | |
3e42bf30 | 20 | and the flag for master/slave status on the DA |
21 | ||
22 | The copy onto the FES for the modified local masks is only done when the flag is set to master for the DA. | |
23 | The DA creates a file (ExportedFiles.dat) containing the name of the files to be transfert by the shuttle. | |
24 | To be able to check the change of version of one the files, another file is created containing the last current | |
25 | list of configuration files: MtgLastCurrent.dat. | |
26 | The Muon trigger electronics could run with two types of calibration: | |
27 | ||
28 | \subsection da_ss1 ELECTRONICS_CALIBRATION_RUN (calib) | |
29 | ||
30 | This procedure allows to check dead channels. The FET pulses are injected to the 21 kchannels. | |
31 | ||
32 | The typical ECS sequence for calib is : | |
33 | ||
34 | - Switch ON the electronics LV | |
35 | - Load Configuration via the MTS package | |
36 | - Enable FET pulse | |
37 | - Data taking (typically 100 events) | |
38 | - The DA computes the occupancy, if a channel is not responding in 80% of the case, it will be marked as dead | |
39 | - The DA update the local mask file accordingly and put it on the File Exchange Server | |
40 | ||
41 | Then the SHUTTLE process the ASCII files and store the configuration on the OCDB | |
42 | ||
43 | This option is disable for the moment. | |
44 | ||
45 | \subsection da_ss2 DETECTOR_CALIBRATION_RUN (ped) | |
46 | ||
47 | This procedure checks the noisy channels. A normal physics run is performed. | |
48 | ||
49 | The typical ECS sequence for calibration is : | |
50 | ||
51 | - Switch ON the electronics LV | |
52 | - Load Configuration via the MTS package | |
53 | - Data taking (typically 100 events) | |
54 | - The DA computes the occupancy, if a channel is responding in 80% of the case, it will be marked as noisy | |
55 | - The DA update the local mask file accordingly and put it on the File Exchange Server | |
56 | ||
57 | Then the SHUTTLE process the ASCII files and store the configuration on the OCDB | |
58 | ||
59 | \section da_s2 Using the DA Online | |
60 | ||
61 | You have a line command help. To have it just type : | |
62 | ||
63 | \verbatim | |
64 | > MUONTRGda.exe -h | |
65 | ||
66 | ******************* MUONTRGda.exe usage ********************** | |
67 | MUONTRGda.exe -options, the available options are : | |
68 | -h help (this screen) | |
69 | ||
70 | Input | |
71 | -f <raw data file> (default = ) | |
72 | ||
73 | output | |
74 | -r <root file> (default = none) | |
75 | ||
76 | Options | |
77 | -t <threshold values> (default = 0.2) | |
78 | -d <print level> (default = 0) | |
79 | -s <skip events> (default = 0) | |
80 | -n <max events> (default = 1000000) | |
81 | -e <execute ped/calib> (default = nil) | |
82 | ||
83 | \endverbatim | |
84 | ||
85 | ||
86 | \section da_s3 In case of trouble | |
87 | ||
88 | Please contact: | |
89 | ||
90 | Franck Manso: manson@clermont.in2p3.fr | |
91 | ||
92 | or | |
93 | ||
94 | Christian Finck: finck@subatech.in2p3.fr (until 01 Septembre 08) | |
95 | ||
96 | ||
97 | This chapter is defined in the READMEmtrda.txt file. | |
98 | */ | |