1 // $Id$
2
3 /*! 
4
5 \page README_mtrda Trigger DA
6  
7 The detector algorithm is implemented for the Muon Trigger in the AliRoot framework.
8 The main code is located in MUONTRGda.cxx and it runs in the MUON Trigger LDC.
9
10 \section da_s1 The Muon Trigger Calibration
11
12 The main goal of the DA is the transfert of the modified configuration files to the FES.
13 The configuration files stored in the online DB are the following:
14
15 MtgGlobalCrate-<version>.dat:   contains the global crate information
16 MtgRegionalCrate-<version>.dat: contains the regional crate information
17 MtgLocalMask-<version>.dat:     contains the local mask
18 MtgLocalLut-<version>.dat:      contains the local LUT 
19 MtgCurrent.dat:                 contains the name list of the above files with their version 
20                                 and the flag for master/slave status on the DA
21
22 The copy onto the FES for the modified local masks is only done when the flag is set to master for the DA.
23 The DA creates a file (ExportedFiles.dat) containing the name of the files to be transfert by the shuttle.
24 To be able to check the change of version of one the files, another file is created containing the last current
25 list of configuration files: MtgLastCurrent.dat.
26 The Muon trigger electronics could run with two types of calibration:
27
28 \subsection da_ss1  ELECTRONICS_CALIBRATION_RUN (calib)
29
30 This procedure allows to check dead channels. The FET pulses are injected to the 21 kchannels.
31
32 The typical ECS sequence for calib is :
33
34 - Switch ON the electronics LV
35 - Load Configuration via the MTS package
36 - Enable FET pulse 
37 - Data taking (typically 100 events)
38 - The DA computes the occupancy, if a channel is not responding in 80% of the case, it will be marked as dead 
39 - The DA update the local mask file accordingly and put it on the File Exchange Server
40
41 Then the SHUTTLE process the ASCII files and store the configuration on the OCDB
42
43 This option is disable for the moment.
44
45 \subsection da_ss2  DETECTOR_CALIBRATION_RUN (ped)
46
47 This procedure checks the noisy channels. A normal physics run is performed.
48
49 The typical ECS sequence for calibration is :
50
51 - Switch ON the electronics LV
52 - Load Configuration via the MTS package
53 - Data taking (typically 100 events)
54 - The DA computes the occupancy, if a channel is responding in 80% of the case, it will be marked as noisy
55 - The DA update the local mask file accordingly and put it on the File Exchange Server
56
57 Then the SHUTTLE process the ASCII files and store the configuration on the OCDB
58
59 \section da_s2 Using the DA Online
60
61 You have a line command help. To have it just type :
62
63 \verbatim
64 > MUONTRGda.exe -h
65
66 ******************* MUONTRGda.exe usage **********************
67 MUONTRGda.exe -options, the available options are :
68 -h help                   (this screen)
69
70  Input
71 -f <raw data file>        (default = )
72
73  output
74 -r <root file>            (default = none)
75
76  Options
77 -t <threshold values>     (default = 0.2)
78 -d <print level>          (default = 0)
79 -s <skip events>          (default = 0)
80 -n <max events>           (default = 1000000)
81 -e <execute ped/calib>    (default = nil)
82
83 \endverbatim
84
85  
86 \section da_s3 In case of trouble
87
88 Please contact:
89
90 Franck Manso: manson@clermont.in2p3.fr
91
92 or 
93
94 Christian Finck: finck@subatech.in2p3.fr (until 01 Septembre 08)