]> git.uio.no Git - u/mrichter/AliRoot.git/blob - MUON/READMEtrigger.txt
Update trigger efficiency values for JPsi and Upsilon standard tests with the default LUT
[u/mrichter/AliRoot.git] / MUON / READMEtrigger.txt
1 // $Id$
2
3 /*! 
4
5 \page README_trigger Trigger
6
7
8 \section trigger_s1  How to reprocess trigger decision from already produced digits
9
10 The MUONTrigger.C macro can be used to check the trigger algorithm w/o 
11 having to (re-)perform simulation and digitalization. 
12 It loads the digits, erase TreeR and store the current trigger output in 
13 TreeR.
14
15 The different trigger outputs can be compared by looking at the GLT branch 
16 of TreeD (filled during simulation) and the TC branch of TreeR (filled from 
17 a copy of TreeD during reconstruction or with this macro).
18 Note: rec points from tracking chamber will be lost.
19
20 Usage:
21 <pre>
22 root [0] .L $ALICE_ROOT/MUON/MUONTrigger.C+
23 root [1] MUONTrigger("galice.root")
24 </pre>
25
26
27 \section trigger_s2 OFFLINE trigger Graphical User Interface (GUI) data quality and debugging tool
28
29 - read digits and local trigger decision from simulated/real data
30 - display the strips in local boards
31 - reprocess trigger decision inside AliRoot
32 - set x/y strips interactively on boards and transfer them to the AliRoot
33   TriggerElectronics, execute trigger algorithm and recover the local trigger
34   decision
35
36 Usage (aliroot):
37 <pre>
38 root [0] new AliMUONTriggerGUI
39 </pre>
40
41 Main window shows the map of the local boards as seen from the I.P.
42 The main window is position sensitive: by focusing a board, the "tip text"
43 shows the board name, the crate name, the board ID and the board
44 internal number in the GUI.
45
46 Menus:
47
48
49 \subsection trigger_s2_sub1 File
50
51 - "Run input" - open a file and start with a given event number:
52               - "your_path/galice.root" to use simulated (or re-created) aliroot digits 
53               - confirm with "Apply (galice)"              
54               - "your_path/rawfilename.root" to use raw data in root format
55               - confirm with "Apply (raw)"
56 - "Control"   - navigate in the tree with events
57 - "Exit"      - exit the main application
58
59
60 \subsection trigger_s2_sub2 Maps
61
62 - "Digits map"   - graphical map showing digits in the four chambers, MT11 ... MT22
63 - "Reset digits" - clean the digits map
64
65 \subsection trigger_s2_sub3 Chambers digit maps
66
67 - "Update" - update the map after:
68              - loading of another event
69              - changing interactively the strip signals in boards GUI
70
71
72 \subsection trigger_s2_sub4 Circuit
73
74 - "Open"   - open a board GUI by circuit (board) number
75
76
77 \subsection trigger_s2_sub5 TriggerDSET, run the trigger algorithm with interactively set strips 
78
79 - this is an interface to AliMUONTriggerElectronics
80 - "Digit store"    - create a digit store (object) with the current board digits (input from the circuit GUI)
81 - "Trigger store"  - create a trigger store (object) from the digit store, using AliMUONTriggerElectronics; 
82 each type of store can be "cleared" and "printed"
83 - "Front End Test" - simulate a FET (all strips fire) on all boards or on a regional board
84 - "Write raw data" - save the trigger store in a raw data file (DATE and ROOT) format
85
86 \subsection trigger_s2_sub6 Circuit GUI ("Circuit/Open" or click on boards map)
87
88 - the window title shows the name of the board, the number and the status
89 - "Draw" visualize x/y strips
90 - "Set/unset" x (or) y strips, on mouse click
91 - "Digits" create board digits from the actual configuration created in the GUI
92 - "Reset" reset modification on strips done interactively
93
94 The sequence to test the trigger algorithm is:
95 - open a board GUI
96 - set some x/y strips
97 - press "Digits" to create board digits
98 - from the TrigerDSET menu create a digit store, then a trigger store and print it to see the trigger
99 decision
100 - write raw data for further investigation
101
102 \section trigger_s3 How to check integrated trigger efficiency
103
104 The MUONTriggerEfficiency.C macro (included in the check scripts) calculates
105 the trigger efficiency for the 2 pt cuts. 
106 The output is stored in MUONTriggerEfficiency.out file.
107
108 Usage:
109 <pre>
110 root [0] .L $ALICE_ROOT/MUON/MUONTriggerEfficiency.C+
111 root [1] MUONTriggerEfficiency()
112 </pre>
113
114 For the CVS default version of the trigger LUT (i.e. lutAptLpt1Hpt1p7.root),
115 Two LUTs are stored in the CDB (/Calib/TriggerLut/)
116 Run0_999999999_v0_s0.root   with Lpt 1.0 GeV and Hpt 1.7 GeV
117 and
118 Run0_999999999_v1_s0.root   with Lpt 0.0 GeV and Hpt 1.0 GeV (default)
119
120 The reference for J/psi and Upsilon is as below
121  For 1000 Jpsi events with:
122 <pre>
123     AliGenParam *gener = new AliGenParam(1, AliGenMUONlib::kJpsi);
124     gener->SetMomentumRange(0,999);
125     gener->SetPtRange(0,100.);
126     gener->SetPhiRange(0., 360.);
127     gener->SetCutOnChild(1);
128     gener->SetChildPhiRange(0.,360.);
129     gener->SetChildThetaRange(171.0,178.0);
130     gener->SetOrigin(0,0,0);          
131     gener->SetForceDecay(kDiMuon);
132     gener->SetTrackingFlag(1);
133 </pre>
134
135  the output should be 
136 <pre>
137   Efficiency Lpt cut = 0.9061 +/- 0.0456
138   Efficiency Hpt cut = 0.6943 +/- 0.0376
139 </pre>
140
141  Similarly, for 1000 Upsilon events, the output should be
142
143 <pre>
144   Efficiency Lpt cut = 0.9872 +/- 0.0458
145   Efficiency Hpt cut = 0.9851 +/- 0.0457
146 </pre>
147
148
149 \section trigger_s4 How to check single muon trigger efficiency versus pt
150
151 The MUONTriggerEfficiencyPt.C macro produces trigger single muon efficiency 
152 versus pt plots for the 2 pt cuts. 
153 Results are compared to the reference (red curves).   
154 To be used with (at least) 10000 events as follows
155 <pre>
156    AliGenBox * gener = new AliGenBox(1);
157    gener->SetPtRange(0.,10.);
158    gener->SetPhiRange(0., 360.);         
159    gener->SetThetaRange(171.000,178.001);
160    gener->SetPart(13);           // or -13
161    gener->SetOrigin(0.,0., 0.);  
162    gener->SetSigma(0.0, 0.0, 0.0);     
163 </pre>
164
165 Outputs are stored in MUONTriggerEfficiencyPt.gif/eps/out files
166 Important note: this macro works with one (real) muon track per event only
167
168 Usage:
169 <pre>
170 root [0] .L $ALICE_ROOT/MUON/MUONTriggerEfficiencyPt.C+
171 root [1] MUONTriggerEfficiencyPt()
172 </pre>
173
174
175 \section trigger_s5 How to get trigger chamber efficiency from data
176
177 Trigger chamber efficiency map is calculated during reconstruction and saved in AliESDs.root
178 In order to view and save the map, use macro MUONTriggerChamberEfficiency.C
179
180 To compile MUONTriggerChamberEfficiency.C
181 <pre>
182 .includepath $ALICE_ROOT/MUON
183 .L $ALICE_ROOT/MUON/MUONTriggerChamberEfficiency.C+
184 </pre>
185
186 To run MUONTriggerChamberEfficiency.C
187 <pre>
188 MUONTriggerChamberEfficiency();
189 </pre>
190
191 If you want to make the calculated map available for next simulation use option kTRUE, i.e.
192 <pre>
193 MUONTriggerChamberEfficiency(kTRUE);
194 </pre>
195
196 When running next simulation, please remember to activate trigger efficiency
197 by adding in Config.C:
198 <pre>
199 MUON->SetTriggerEffCells(1);
200 </pre>
201
202 This chapter is defined in the READMEtrigger.txt file.