const TString kPedestalRunType = "PEDESTAL"; // pedestal run identifier
const TString kPhysicsRunType = "PHYSICS"; // physics run identifier
const TString kStandAloneRunType = "STANDALONE"; // standalone run identifier
-const TString kAmandaTemp = "PT_%02d_TEMPERATURE"; // Amanda string for temperature entries
+const TString kAmandaTemp = "PT_%02d.Temperature"; // Amanda string for temperature entries
//const Double_t kFitFraction = 0.7; // Fraction of DCS sensor fits required
const Double_t kFitFraction = -1.0; // Don't require minimum number of fits during commissioning
TList* list = GetFileSources(sourceFXS,"signal");
if (list && list->GetEntries()>0) {
+
+ /* DS: 17 June 2008 - commented out this reset to avoid crash in shuttle.
+ Not sure why it occurs, in standalone tests a Reset() seemed to work OK..
calibSig->Reset(); // let's make a fresh start before possibly adding stuff below
+ */
// loop through all files from LDCs