1) AliAnalysisTaskESDMuonFilter.h --> analysis task to copy the muon information from the ESD to the standard AOD
2) AliAnalysisTaskESDMuonFilter.cxx --> analysis task to copy the muon information from the ESD to the standard AOD
-In order to test locally the analysis train from the ESD to the Standard AOD production, the following macro is provided
-
-1) AnalysisTrainMuonLocal.C
- - The input file is the ESD
- - The outputs are the standard AOD and the AOD tag file
+In order to test the analysis train from the ESD to the Standard AOD production, the following macro is provided:
+
+ AnalysisTrainFromESDToAOD.C
+
+Input file: ESD
+Output files: standard AOD (+AOD tags)
+
+Two wagons are attached to the analysis train:
+ 1) $ALICE_ROOT/ANALYSIS/macros/AddTaskESDFilter.C
+ 2) $ALICE_ROOT/PWG3/muon/AddTaskTagCreation.C
+
+Several flags can be activated:
+ 1) iESDfilter: to activate, using AddTaskESDFilter.C, the copy of the ESD information into the AOD.
+ In AddTaskESDFilter.C there is the possibility to apply cuts on the tracks and muon tracks in order
+ to reject them before filling the AOD.
+ 2) iAODAddMCBranch: to activate the inclusion of the MC branch (containing Kinematics info) into a branch of the AOD
+ 3) iAODTagCreation: to activate, using AddTaskTagCreation.C, the AOD tag creation
+
+Runninng options tested:
+ 1) GRID (with/without AliEn plugin)
+ 2) LOCAL
+
+If the AliEn plugin is required, the macro
+ CreateAlienHandler_FromESDToAOD.C
+can be used, in order to configure the jdl.
+
+AnalysisTrainFromESDToAOD.C is an updated version of the macro AnalysisTrainMuonLocal.C
+(input file: ESD, output files standard AOD and the AOD tag file)
+The main differences are related to implementations to be compliant with the analysis framework,
+possibility to run on the grid with/without the Alien Plugin and possibility of adding the MC truth in a branch of the AOD.
+
+The macro ReadAOD_MCBranch.C is an example on how to access MC information stored in the AOD.
===================================================
Creation of the MUON-AOD from the standard AOD