public:
enum EOfflineTriggerTypes {
kMB = BIT(0), // Minimum bias trigger, i.e. interaction trigger, offline SPD or V0 selection
- // empty slot
kINT7 = BIT(1), // V0AND trigger, offline V0 selection
kMUON = BIT(2), // Muon trigger, offline SPD or V0 selection
kHighMult = BIT(3), // High-multiplicity trigger (threshold defined online), offline SPD or V0 selection
kEMC1 = BIT(4), // EMCAL trigger
kCINT5 = BIT(5), // Minimum bias trigger without SPD. i.e. interaction trigger, offline V0 selection
kCMUS5 = BIT(6), // Muon trigger, offline V0 selection
+ kMUSPB = BIT(6), // idem for PbPb
kMUSH7 = BIT(7), // Muon trigger: high pt, single muon, offline V0 selection, CINT7 suite
+ kMUSHPB = BIT(7), // idem for PbPb
kMUL7 = BIT(8), // Muon trigger: like sign dimuon, offline V0 selection, CINT7 suite
+ kMuonLikePB = BIT(8), // idem for PbPb
kMUU7 = BIT(9), // Muon trigger, unlike sign dimuon, offline V0 selection, CINT7 suite
+ kMuonUnlikePB = BIT(9), // idem for PbPb
kEMC7 = BIT(10), // EMCAL trigger, CINT7 suite
kMUS7 = BIT(11), // Muon trigger: low pt, single muon, offline V0 selection, CINT7 suite
kPHI1 = BIT(12), // PHOS trigger, CINT1 suite
kPHI7 = BIT(13), // PHOS trigger, CINT7 suite
+ kEMCEJE = BIT(14), // EMCAL jet patch trigger
+ kEMCEGA = BIT(15), // EMCAL gamma trigger
+ kCentral = BIT(16), // PbPb central collision trigger
+ kSemiCentral = BIT(17), // PbPb semicentral collision trigger
kUserDefined = BIT(27), // Set when custom trigger classes are set in AliPhysicsSelection, offline SPD or V0 selection
- // Bits 28 and abovr are served for FLAGS
+ // Bits 28 and above are reserved for FLAGS
kFastOnly = BIT(30), // The fast cluster fired. This bit is set in to addition another trigger bit, e.g. kMB
kAny = 0xffffffff, // to accept any trigger
kAnyINT = kMB | kINT7 | kCINT5 // to accept any interaction (aka minimum bias) trigger