3 Alignment of the V0A and the beam pipe support on the Front Absorber
15 https://edms.cern.ch/document/906073
21 > General Observations:
23 A photogrammetric measurement has been performed to the V0A detector on July 6. This data is used to provide the new alignment of the detector.
39 Point Name,XPH,YPH,ZPH,Point Type,Target Used,Precision(mm)
44 V0A_IAB 21.85 -808.39 3311.32 M Y 1
45 V0A_IAM 628.45 141.86 3316.89 M Y 1
46 V0A_IAT 119.16 637.89 3322.29 M Y 1
47 ST_IAB 132.47 -683.26 3304.33 M Y 1
48 ST_IAM 533.52 -20.01 3308.81 M Y 1
49 ST_IAT 131.76 529.72 3314.10 M Y 1
50 V0A_OAB -19.17 -808.80 3311.60 M Y 1
51 V0A_OAM -628.59 139.49 3321.70 M Y 1
52 V0A_OAT -119.97 637.00 3323.35 M Y 1
53 ST_OAB -142.40 -695.35 3304.44 M Y 1
54 ST_OAM -529.89 20.79 3312.76 M Y 1
55 ST_OAT -139.89 503.11 3314.74 M Y 1
56 ST_ICB 20.51 -327.44 3250.64 M Y 1
57 ST_ICM 306.53 6.02 3254.64 M Y 1
58 ST_ICT 16.38 283.03 3257.77 M Y 1
59 ST_OCB -15.99 -325.09 3253.22 M Y 1
60 ST_OCM -295.60 18.40 3255.47 M Y 1
61 ST_OCT -11.01 279.35 3257.42 M Y 1
62 6001 127.43 -218.82 3250.64 M Y 1
63 6002 126.76 221.07 3253.92 M Y 1
64 6003 -126.77 -219.13 3250.43 M Y 1
65 6004 -127.19 220.77 3253.75 M Y 1